Vascular pressure bands on high-resolution esophageal manometry with impedance studies. Issue 3 (11th December 2019)
- Record Type:
- Journal Article
- Title:
- Vascular pressure bands on high-resolution esophageal manometry with impedance studies. Issue 3 (11th December 2019)
- Main Title:
- Vascular pressure bands on high-resolution esophageal manometry with impedance studies
- Authors:
- Lis, Steffen
Vachhani, Herit
Tanner, Samuel
Leopold, Andrew
Zitomer, Samantha
Bhuta, Rajiv
Schey, Ron
Malik, Zubair
P Parkman, Henry - Abstract:
- ABSTRACT: Horizontal pressure bands on high-resolution esophageal manometry with impedance (HREMI) tracings are often seen and thought to be due to cardiovascular structures compressing the esophagus. The aim of this study was to determine the prevalence and location of vascular pressure bands on HREMI studies and correlate these pressure bands to bolus clearance. HREMI studies in supine and upright positions from patients and normal volunteers were reviewed. Pressure bands were defined as bands of horizontal pressure greater than the 20 mmHg isobaric contour. Each swallow was reviewed with impedance to determine if bolus transit was impaired by the band. 38.6% of 251 patients and 36.4% of 11 normal controls had a pressure band present. There were a greater number of bands in supine versus upright position (patients: 130 vs. 25, P < 0.001 and controls: 6 vs. 1). Patients with pressure bands had similar demographics (age, gender, BMI) compared to those without. Average distal contractile integral of bands was greater in supine compared to upright (133 ± 201 vs. 60 ± 148 mmHg cm s, P < 0.05). Bands were commonly located clustered at 46 and 72% of esophageal length. Bolus transit was impaired by bands in 20.4% of supine and 14.0% of upright swallows. Vascular pressure bands can have a prominent appearance on HREMI studies, present in, being more prevalent and having greater pressure in the supine than the upright position. These vascular bands, when present, may impairABSTRACT: Horizontal pressure bands on high-resolution esophageal manometry with impedance (HREMI) tracings are often seen and thought to be due to cardiovascular structures compressing the esophagus. The aim of this study was to determine the prevalence and location of vascular pressure bands on HREMI studies and correlate these pressure bands to bolus clearance. HREMI studies in supine and upright positions from patients and normal volunteers were reviewed. Pressure bands were defined as bands of horizontal pressure greater than the 20 mmHg isobaric contour. Each swallow was reviewed with impedance to determine if bolus transit was impaired by the band. 38.6% of 251 patients and 36.4% of 11 normal controls had a pressure band present. There were a greater number of bands in supine versus upright position (patients: 130 vs. 25, P < 0.001 and controls: 6 vs. 1). Patients with pressure bands had similar demographics (age, gender, BMI) compared to those without. Average distal contractile integral of bands was greater in supine compared to upright (133 ± 201 vs. 60 ± 148 mmHg cm s, P < 0.05). Bands were commonly located clustered at 46 and 72% of esophageal length. Bolus transit was impaired by bands in 20.4% of supine and 14.0% of upright swallows. Vascular pressure bands can have a prominent appearance on HREMI studies, present in, being more prevalent and having greater pressure in the supine than the upright position. These vascular bands, when present, may impair esophageal transit. … (more)
- Is Part Of:
- Diseases of the esophagus. Volume 33:Issue 3(2020)
- Journal:
- Diseases of the esophagus
- Issue:
- Volume 33:Issue 3(2020)
- Issue Display:
- Volume 33, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 33
- Issue:
- 3
- Issue Sort Value:
- 2020-0033-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12-11
- Subjects:
- dysphagia -- esophageal manometry -- high-resolution esophageal manometry
Esophagus -- Diseases -- Periodicals
616.32 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1442-2050 ↗
http://www.wiley.com/bw/journal.asp?ref=1120-8694 ↗
https://academic.oup.com/dote ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1093/dote/doz093 ↗
- Languages:
- English
- ISSNs:
- 1120-8694
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3598.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20851.xml