Canadian Association of Gastroenterology Communique: After-Hours Endoscopy Cart. Issue 5 (21st November 2019)
- Record Type:
- Journal Article
- Title:
- Canadian Association of Gastroenterology Communique: After-Hours Endoscopy Cart. Issue 5 (21st November 2019)
- Main Title:
- Canadian Association of Gastroenterology Communique: After-Hours Endoscopy Cart
- Authors:
- Rai, Mandip
Cooper, Mary
Shulman, Scott
Kottachchi, Dan
Nelles, Sandra
Macmillan, Mark
Heitman, Steven
Barkun, Alan
Tse, Frances
Hookey, Lawrence - Abstract:
- Abstract: Background: Endoscopic procedures performed after-hours often require therapeutic interventions that are technically demanding for the endoscopist. The aim of this position paper is to provide guidance on the minimum standard of equipment that should be available on a mobile endoscopy cart for provision of a safe and effective after-hours emergency endoscopy service. The guidance is based on consensus among academic and community gastroenterologists in Canada. Methods: A modified Delphi process was used to establish consensus among 9 participants. A list of statements was prepared by an expert panel of endoscopists. The statements were divided into three broad sections for what should be on an after-hours endoscopy cart including medications, nonendoscopic tools and therapeutic/diagnostic equipment. Consensus for being on the endoscopy cart was achieved when 75% or more of voting members indicated 'agree'. Results: For nonendoscopic tools, there was agreement for having sterile saline, sterile water, endoscope lubricant, various syringes, bite blocks (paediatric and adult size), a water pump with foot peddle, formalin jars for biopsy specimens, digital photo and printing capability and an overtube. For medications, there was agreement for having hyoscine butylbromide and epinephrine on the cart. For therapeutic/diagnostic tools, there was agreement for having biopsy forceps (standard and jumbo), polypectomy snares, sclerotherapy needles and agent (for a varicealAbstract: Background: Endoscopic procedures performed after-hours often require therapeutic interventions that are technically demanding for the endoscopist. The aim of this position paper is to provide guidance on the minimum standard of equipment that should be available on a mobile endoscopy cart for provision of a safe and effective after-hours emergency endoscopy service. The guidance is based on consensus among academic and community gastroenterologists in Canada. Methods: A modified Delphi process was used to establish consensus among 9 participants. A list of statements was prepared by an expert panel of endoscopists. The statements were divided into three broad sections for what should be on an after-hours endoscopy cart including medications, nonendoscopic tools and therapeutic/diagnostic equipment. Consensus for being on the endoscopy cart was achieved when 75% or more of voting members indicated 'agree'. Results: For nonendoscopic tools, there was agreement for having sterile saline, sterile water, endoscope lubricant, various syringes, bite blocks (paediatric and adult size), a water pump with foot peddle, formalin jars for biopsy specimens, digital photo and printing capability and an overtube. For medications, there was agreement for having hyoscine butylbromide and epinephrine on the cart. For therapeutic/diagnostic tools, there was agreement for having biopsy forceps (standard and jumbo), polypectomy snares, sclerotherapy needles and agent (for a variceal bleed), band ligation kit, multipolar electrocautery probes, heater probe catheter, endoscopic clips, hemostatic powder and retrieval devices. Interpretation: This position paper provides guidance on the minimum standard of items that should be on an after-hours endoscopy cart. Standardization of equipment may help improve safety and quality of after-hours endoscopic procedures. … (more)
- Is Part Of:
- Journal of the Canadian Association of Gastroenterology. Volume 3:Issue 5(2020)
- Journal:
- Journal of the Canadian Association of Gastroenterology
- Issue:
- Volume 3:Issue 5(2020)
- Issue Display:
- Volume 3, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 3
- Issue:
- 5
- Issue Sort Value:
- 2020-0003-0005-0000
- Page Start:
- 222
- Page End:
- 227
- Publication Date:
- 2019-11-21
- Subjects:
- After-hours endoscopy -- Therapeutic endoscopy -- Upper gastrointestinal bleed
Gastroenterology -- Periodicals
616.33005 - Journal URLs:
- https://academic.oup.com/jcag ↗
http://www.oxfordjournals.org/ ↗ - DOI:
- 10.1093/jcag/gwz032 ↗
- Languages:
- English
- ISSNs:
- 2515-2084
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20854.xml