An unbiased, efficient sleep–wake detection algorithm for a population with sleep disorders: change point decoder. Issue 8 (1st February 2020)
- Record Type:
- Journal Article
- Title:
- An unbiased, efficient sleep–wake detection algorithm for a population with sleep disorders: change point decoder. Issue 8 (1st February 2020)
- Main Title:
- An unbiased, efficient sleep–wake detection algorithm for a population with sleep disorders: change point decoder
- Authors:
- Cakmak, Ayse S
Da Poian, Giulia
Willats, Adam
Haffar, Ammer
Abdulbaki, Rami
Ko, Yi-An
Shah, Amit J
Vaccarino, Viola
Bliwise, Donald L
Rozell, Christopher
Clifford, Gari D - Abstract:
- Abstract: Study Objectives: The usage of wrist-worn wearables to detect sleep–wake states remains a formidable challenge, particularly among individuals with disordered sleep. We developed a novel and unbiased data-driven method for the detection of sleep–wake and compared its performance with the well-established Oakley algorithm (OA) relative to polysomnography (PSG) in elderly men with disordered sleep. Methods: Overnight in-lab PSG from 102 participants was compared with accelerometry and photoplethysmography simultaneously collected with a wearable device (Empatica E4). A binary segmentation algorithm was used to detect change points in these signals. A model that estimates sleep or wake states given the changes in these signals was established (change point decoder, CPD). The CPD's performance was compared with the performance of the OA in relation to PSG. Results: On the testing set, OA provided sleep accuracy of 0.85, wake accuracy of 0.54, AUC of 0.67, and Kappa of 0.39. Comparable values for CPD were 0.70, 0.74, 0.78, and 0.40. The CPD method had sleep onset latency error of −22.9 min, sleep efficiency error of 2.09%, and underestimated the number of sleep–wake transitions with an error of 64.4. The OA method's performance was 28.6 min, −0.03%, and −17.2, respectively. Conclusions: The CPD aggregates information from both cardiac and motion signals for state determination as well as the cross-dimensional influences from these domains. Therefore, CPD classificationAbstract: Study Objectives: The usage of wrist-worn wearables to detect sleep–wake states remains a formidable challenge, particularly among individuals with disordered sleep. We developed a novel and unbiased data-driven method for the detection of sleep–wake and compared its performance with the well-established Oakley algorithm (OA) relative to polysomnography (PSG) in elderly men with disordered sleep. Methods: Overnight in-lab PSG from 102 participants was compared with accelerometry and photoplethysmography simultaneously collected with a wearable device (Empatica E4). A binary segmentation algorithm was used to detect change points in these signals. A model that estimates sleep or wake states given the changes in these signals was established (change point decoder, CPD). The CPD's performance was compared with the performance of the OA in relation to PSG. Results: On the testing set, OA provided sleep accuracy of 0.85, wake accuracy of 0.54, AUC of 0.67, and Kappa of 0.39. Comparable values for CPD were 0.70, 0.74, 0.78, and 0.40. The CPD method had sleep onset latency error of −22.9 min, sleep efficiency error of 2.09%, and underestimated the number of sleep–wake transitions with an error of 64.4. The OA method's performance was 28.6 min, −0.03%, and −17.2, respectively. Conclusions: The CPD aggregates information from both cardiac and motion signals for state determination as well as the cross-dimensional influences from these domains. Therefore, CPD classification achieved balanced performance and higher AUC, despite underestimating sleep–wake transitions. The CPD could be used as an alternate framework to investigate sleep–wake dynamics within the conventional time frame of 30-s epochs. … (more)
- Is Part Of:
- Sleep. Volume 43:Issue 8(2020)
- Journal:
- Sleep
- Issue:
- Volume 43:Issue 8(2020)
- Issue Display:
- Volume 43, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 8
- Issue Sort Value:
- 2020-0043-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-02-01
- Subjects:
- sleep/wake -- change point detection -- wearable device -- actigraphy -- heart rate
Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsaa011 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20861.xml