Development and Validation of a Novel, Rapid Gradient HPLC Method for Simultaneous Estimation of Bioactive Marker Compounds in a Mixture of Convolvulus pluricaulis, Withania somnifera and Bacopa monnieri Extracts. (21st October 2019)
- Record Type:
- Journal Article
- Title:
- Development and Validation of a Novel, Rapid Gradient HPLC Method for Simultaneous Estimation of Bioactive Marker Compounds in a Mixture of Convolvulus pluricaulis, Withania somnifera and Bacopa monnieri Extracts. (21st October 2019)
- Main Title:
- Development and Validation of a Novel, Rapid Gradient HPLC Method for Simultaneous Estimation of Bioactive Marker Compounds in a Mixture of Convolvulus pluricaulis, Withania somnifera and Bacopa monnieri Extracts
- Authors:
- Choudhary, Sunayna
Kaur, Indu Pal
Malik, Jai - Abstract:
- Abstract: The use of herbs as medicine is an ancient form of healthcare known to mankind. Standardization of herbal medicines is however a challenging task and is the major bottleneck in their acceptance as the primary therapeutic option. The aim of this study was to develop and validate a simple, rapid HPLC method for standardizing the mixture of extracts of three Medhya Rasayanas (neurotonic), Convolvulus pluricaulis, Withania somnifera and Bacopa monnieri . Simultaneous estimation of the respective bioactive markers of these plants viz., scopoletin, withaferin A, bacoside A 3, bacopaside II, jujubogenin and bacosaponin C has been reported for the first time. The method was developed using Waters Hybrid X-Bridge shield with BEH technology 2.5 μm, 4.6 × 75 mm column and validated according to ICH guidelines. The 20 minutes run time makes the method eco-friendly. The method was linear over a range of 12.5–400 ng/10 μL for scopoletin and 62.5–2, 000 ng/10 μL for withaferin A, bacoside A 3, bacopaside II, jujubogenin and bacosaponin C with detection limits of 8.0, 48.3, 30.4, 40.7, 15.6 and 18.9 ng/10 μL and quantification limits of 24.5, 146.5, 92.2, 123.4, 47.4 and 57.4 ng/10 μL, respectively. The correlation coefficient for each analyte was >0.999. The intra-day and inter-day precision was <2%. These results confirmed the precision, accuracy and robustness of the proposed method.
- Is Part Of:
- Journal of chromatographic science. Volume 57:Number 10(2019)
- Journal:
- Journal of chromatographic science
- Issue:
- Volume 57:Number 10(2019)
- Issue Display:
- Volume 57, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 57
- Issue:
- 10
- Issue Sort Value:
- 2019-0057-0010-0000
- Page Start:
- 920
- Page End:
- 930
- Publication Date:
- 2019-10-21
- Subjects:
- Chromatographic analysis -- Periodicals
543.8 - Journal URLs:
- http://chromsci.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/chromsci/bmz075 ↗
- Languages:
- English
- ISSNs:
- 0021-9665
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20843.xml