Five-year clinical outcomes of the first Korean-made sirolimus-eluting coronary stent with abluminal biodegradable polymer. Issue 19 (14th May 2021)
- Record Type:
- Journal Article
- Title:
- Five-year clinical outcomes of the first Korean-made sirolimus-eluting coronary stent with abluminal biodegradable polymer. Issue 19 (14th May 2021)
- Main Title:
- Five-year clinical outcomes of the first Korean-made sirolimus-eluting coronary stent with abluminal biodegradable polymer
- Authors:
- Seo, Kyoung-Woo
Yang, Hyoung-Mo
Yoon, Junghan
Kim, Hyo-Soo
Chang, Kiyuk
Lim, Hong-Seok
Choi, Byoung-Joo
Choi, So-Yeon
Yoon, Myeong-Ho
Lee, Seung-Hwan
Ahn, Sung Gyun
Youn, Young Jin
Lee, Jun-Won
Koo, Bon-Kwon
Park, Kyung Woo
Yang, Han-Mo
Han, Jung-Kyu
Chung, Wook-Sung
Park, Hun-Jun
Hwang, Byung-Hee
Choo, Eun-Ho
Oh, Gyu-Chul
Tahk, Seung-Jea - Other Names:
- Roever. Leonardo section editor.
- Abstract:
- Abstract : Abstract: This study evaluated the 5-year clinical outcomes of the Genoss DES, the first Korean-made sirolimus-eluting coronary stent with abluminal biodegradable polymer. We previously conducted the first-in-patient prospective, multicenter, randomized trial with a 1:1 ratio of patients using the Genoss DES and Promus Element stents; the angiographic and clinical outcomes of the Genoss DES stent were comparable to those of the Promus Element stent. The primary endpoint was major adverse cardiac events (MACE), which was a composite of death, myocardial infarction (MI), and target lesion revascularization (TLR) at 5 years. We enrolled 38 patients in the Genoss DES group and 39 in the Promus Element group. Thirty-eight patients (100%) from the Genoss DES group and 38 (97.4%) from the Promus Element group were followed up at 5 years. The rates of MACE (5.3% vs 12.8%, P = .431), death (5.3% vs 10.3%, P = .675), TLR (2.6% vs 2.6%, P = 1.000), and target vessel revascularization (TVR) (7.9% vs 2.6%, P = .358) at 5 years did not differ significantly between the groups. No TLR or target vessel revascularization was reported from years 1 to 5 after the index procedure, and no MI or stent thrombosis occurred in either group during 5 years. The biodegradable polymer Genoss DES and durable polymer Promus Element stents showed comparable low rates of MACE at the 5-year clinical follow-up.
- Is Part Of:
- Medicine. Volume 100:Issue 19(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 19(2021)
- Issue Display:
- Volume 100, Issue 19 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 19
- Issue Sort Value:
- 2021-0100-0019-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-05-14
- Subjects:
- coronary artery disease -- drug-eluting stents -- Sirolimus
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000025765 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20847.xml