Automated pulse wave velocity assessment using a professional oscillometric office blood pressure monitor. Issue 10 (6th August 2020)
- Record Type:
- Journal Article
- Title:
- Automated pulse wave velocity assessment using a professional oscillometric office blood pressure monitor. Issue 10 (6th August 2020)
- Main Title:
- Automated pulse wave velocity assessment using a professional oscillometric office blood pressure monitor
- Authors:
- Kollias, Anastasios
Kyriakoulis, Konstantinos G.
Gravvani, Areti
Anagnostopoulos, Ioannis
Stergiou, George S. - Abstract:
- Abstract: Carotid‐femoral pulse wave velocity (cfPWV) is the gold standard method for assessing arterial stiffness. This study evaluated automated brachial‐ankle PWV (baPWV) taken by a professional oscillometric blood pressure monitor (Microlife WatchBP Office Vascular) versus reference cfPWV (Complior device). Subjects recruited from a hypertension outpatient clinic had duplicate baPWV and cfPWV measurements (randomized crossover design) and carotid ultrasonography. Of 102 subjects recruited, 101 had valid baPWV measurements. Four subjects were excluded and 97 were analyzed (age 58.3 ± 11.4 years, men 70%, hypertensives 76%, diabetics 17%, cardiovascular disease 10%, smokers 23%). The mean difference between baPWV (13.1 ± 1.8 m/s) and cfPWV (9.1 ± 1.8 m/s) was 4.0 ± 1.4 m/s ( P < .01) with close association between them ( r = 0.70, P < .01). baPWV and cfPWV were correlated with age ( r 0.54/0.49 respectively), systolic blood pressure (0.45/0.50), carotid intima‐media thickness (0.31/0.44), and carotid distensibility coefficient (−0.47/−0.34) (all P < .05; no difference between the two methods, z test). There was reasonable agreement (77%) between the two methods in identifying subjects at the top quartile of their distributions (kappa 0.39, P < .01). The areas under the receiver operating characteristic curves for the identification of carotid plaques were comparable for cfPWV and baPWV (0.79 and 0.74 respectively, P = NS). Automated baPWV measurement by aAbstract: Carotid‐femoral pulse wave velocity (cfPWV) is the gold standard method for assessing arterial stiffness. This study evaluated automated brachial‐ankle PWV (baPWV) taken by a professional oscillometric blood pressure monitor (Microlife WatchBP Office Vascular) versus reference cfPWV (Complior device). Subjects recruited from a hypertension outpatient clinic had duplicate baPWV and cfPWV measurements (randomized crossover design) and carotid ultrasonography. Of 102 subjects recruited, 101 had valid baPWV measurements. Four subjects were excluded and 97 were analyzed (age 58.3 ± 11.4 years, men 70%, hypertensives 76%, diabetics 17%, cardiovascular disease 10%, smokers 23%). The mean difference between baPWV (13.1 ± 1.8 m/s) and cfPWV (9.1 ± 1.8 m/s) was 4.0 ± 1.4 m/s ( P < .01) with close association between them ( r = 0.70, P < .01). baPWV and cfPWV were correlated with age ( r 0.54/0.49 respectively), systolic blood pressure (0.45/0.50), carotid intima‐media thickness (0.31/0.44), and carotid distensibility coefficient (−0.47/−0.34) (all P < .05; no difference between the two methods, z test). There was reasonable agreement (77%) between the two methods in identifying subjects at the top quartile of their distributions (kappa 0.39, P < .01). The areas under the receiver operating characteristic curves for the identification of carotid plaques were comparable for cfPWV and baPWV (0.79 and 0.74 respectively, P = NS). Automated baPWV measurement by a professional oscillometric blood pressure monitor is feasible and observer‐independent. baPWV values differ from those by cfPWV, yet they are closely correlated, have reasonable agreement in detecting increased arterial stiffness and give similar associations with carotid stiffness and atherosclerosis. … (more)
- Is Part Of:
- Journal of clinical hypertension. Volume 22:Issue 10(2020)
- Journal:
- Journal of clinical hypertension
- Issue:
- Volume 22:Issue 10(2020)
- Issue Display:
- Volume 22, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 10
- Issue Sort Value:
- 2020-0022-0010-0000
- Page Start:
- 1817
- Page End:
- 1823
- Publication Date:
- 2020-08-06
- Subjects:
- brachial‐ankle pulse wave velocity -- arterial stiffness -- automated -- validation
Hypertension -- Periodicals
616.132 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-7176 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.blackwell-synergy.com/loi/jch ↗ - DOI:
- 10.1111/jch.13966 ↗
- Languages:
- English
- ISSNs:
- 1524-6175
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.484100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20815.xml