Quantification of Subdural Electrode Shift Between Initial Implantation, Postimplantation Computed Tomography, and Subsequent Resection Surgery. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Quantification of Subdural Electrode Shift Between Initial Implantation, Postimplantation Computed Tomography, and Subsequent Resection Surgery. Issue 1 (January 2019)
- Main Title:
- Quantification of Subdural Electrode Shift Between Initial Implantation, Postimplantation Computed Tomography, and Subsequent Resection Surgery
- Authors:
- Fan, Xiaoyao
Roberts, David W
Kamal, Yasmin
Olson, Jonathan D
Paulsen, Keith D - Abstract:
- Abstract : BACKGROUND: : Subdural electrodes are often implanted for localization of epileptic regions. Postoperative computed tomography (CT) is typically acquired to locate electrode positions for planning any subsequent surgical resection. Electrodes are assumed to remain stationary between CT acquisition and resection surgery. OBJECTIVE: : To quantify subdural electrode shift that occurred between the times of implantation (Crani 1), postoperative CT acquisition, and resection surgery (Crani 2). METHODS: : Twenty‐three patients in this case series undergoing subdural electrode implantation were evaluated. Preoperative magnetic resonance and postoperative CT were acquired and coregistered, and electrode positions were extracted from CT. Intraoperative positions of electrodes and the cortical surface were digitized with a coregistered stereovision system. Movement of the exposed cortical surface was also tracked, and change in electrode positions was calculated relative to both the skull and the cortical surface. RESULTS: : In the 23 cases, average shift of electrode positions was 8.0 ± 3.3 mm between Crani 1 and CT, 9.2 ± 3.7 mm between CT and Crani 2, and 6.2 ± 3.0 mm between Crani 1 and Crani 2. The average cortical shift was 4.7 ± 1.4 mm with 2.9 ± 1.0 mm in the lateral direction. The average shift of electrode positions relative to the cortical surface between Crani 1 and Crani 2 was 5.5 ± 3.7 mm. CONCLUSION: : The results show that electrodes shifted laterally notAbstract : BACKGROUND: : Subdural electrodes are often implanted for localization of epileptic regions. Postoperative computed tomography (CT) is typically acquired to locate electrode positions for planning any subsequent surgical resection. Electrodes are assumed to remain stationary between CT acquisition and resection surgery. OBJECTIVE: : To quantify subdural electrode shift that occurred between the times of implantation (Crani 1), postoperative CT acquisition, and resection surgery (Crani 2). METHODS: : Twenty‐three patients in this case series undergoing subdural electrode implantation were evaluated. Preoperative magnetic resonance and postoperative CT were acquired and coregistered, and electrode positions were extracted from CT. Intraoperative positions of electrodes and the cortical surface were digitized with a coregistered stereovision system. Movement of the exposed cortical surface was also tracked, and change in electrode positions was calculated relative to both the skull and the cortical surface. RESULTS: : In the 23 cases, average shift of electrode positions was 8.0 ± 3.3 mm between Crani 1 and CT, 9.2 ± 3.7 mm between CT and Crani 2, and 6.2 ± 3.0 mm between Crani 1 and Crani 2. The average cortical shift was 4.7 ± 1.4 mm with 2.9 ± 1.0 mm in the lateral direction. The average shift of electrode positions relative to the cortical surface between Crani 1 and Crani 2 was 5.5 ± 3.7 mm. CONCLUSION: : The results show that electrodes shifted laterally not only relative to the skull, but also relative to the cortical surface, thereby displacing the electrodes from their initial placement on the cortex. This has significant clinical implications for resection based upon seizure activity and functional mapping derived from intracranial electrodes. … (more)
- Is Part Of:
- Operative neurosurgery. Volume 16:Issue 1(2019)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 16:Issue 1(2019)
- Issue Display:
- Volume 16, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2019-0016-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- Epilepsy -- Cortical shift -- Functional mapping -- Intraoperative stereovision -- Optical flow -- Subdural electrode
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1093/ons/opy050 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20828.xml