High correlation between mechanical properties and bone mineral parameters in embalmed femurs after long-term storage. (November 2018)
- Record Type:
- Journal Article
- Title:
- High correlation between mechanical properties and bone mineral parameters in embalmed femurs after long-term storage. (November 2018)
- Main Title:
- High correlation between mechanical properties and bone mineral parameters in embalmed femurs after long-term storage
- Authors:
- Wright, Bryan
Ragan, Lydia
Niratisairak, Sanyalak
Høiseth, Arne
Strømsøe, Knut
Steen, Harald
Brattgjerd, Jan Egil - Abstract:
- Abstract: Background: Fresh frozen human femurs are considered "the gold standard" in biomechanical studies of hip fractures, resembling the in vivo situation mostly. A more readily available alternative is formalin embalmed femurs. However, to which extent formalin affects key features of bone; its mechanical properties, bone mineral content and their mutual relationship over time, remains unknown. Accordingly, we measured the mineral parameters and related them to the mechanical properties of formalin fixed femurs after long-term storage. Methods: 36 paired femurs from human donors, fixed in formalin and stored for a mean period of 4.6 (3.5–6) years. Quantitative CT was performed to measure the bone mineral density and mass at the mainly cortical mid shaft and the center of the mainly cancellous condyles. Each pair was subjected to local tests by three-point bending and screw pullout of the shaft and lateral punch and metaphyseal cube compression of the condyles. Findings: Neither mechanical nor bone mineral data were significantly correlated to storage time. Well-known associations for bone parameters with age and gender were retrieved. Maximum force of the cortical bone tests was highly correlated to the diaphyseal bone mass; (r = 0.80–0.87, p = 0.01), while maximum force of the cancellous bone tests correlated well to the density of the condylar bone; (r = 0.70, p = 0.01). Interpretation: Our results indicate that mechanical and bone mineral data and their mutualAbstract: Background: Fresh frozen human femurs are considered "the gold standard" in biomechanical studies of hip fractures, resembling the in vivo situation mostly. A more readily available alternative is formalin embalmed femurs. However, to which extent formalin affects key features of bone; its mechanical properties, bone mineral content and their mutual relationship over time, remains unknown. Accordingly, we measured the mineral parameters and related them to the mechanical properties of formalin fixed femurs after long-term storage. Methods: 36 paired femurs from human donors, fixed in formalin and stored for a mean period of 4.6 (3.5–6) years. Quantitative CT was performed to measure the bone mineral density and mass at the mainly cortical mid shaft and the center of the mainly cancellous condyles. Each pair was subjected to local tests by three-point bending and screw pullout of the shaft and lateral punch and metaphyseal cube compression of the condyles. Findings: Neither mechanical nor bone mineral data were significantly correlated to storage time. Well-known associations for bone parameters with age and gender were retrieved. Maximum force of the cortical bone tests was highly correlated to the diaphyseal bone mass; (r = 0.80–0.87, p = 0.01), while maximum force of the cancellous bone tests correlated well to the density of the condylar bone; (r = 0.70, p = 0.01). Interpretation: Our results indicate that mechanical and bone mineral data and their mutual relationship are conserved in formalin fixed femurs even after long-term storage. Formalin fixed femurs may serve as an alternative to fresh frozen femurs in biomechanical testing. Highlights: Formalin fixed bone is disputed as a viable option for orthopedic implant testing. Human femur mechanical properties are directly related to bone mineral parameters. Long-term (4 years) storage of embalmed femurs tested Relationship between mechanical properties and bone mineral parameters remains intact. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 59(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 59(2018)
- Issue Display:
- Volume 59, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 2018
- Issue Sort Value:
- 2018-0059-2018-0000
- Page Start:
- 136
- Page End:
- 142
- Publication Date:
- 2018-11
- Subjects:
- Embalmed -- Bone mechanics -- Formalin fixed
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.09.013 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20831.xml