The effects of vibro-medical insole on sensation and plantar pressure distribution in diabetic patients with mild-to-moderate peripheral neuropathy. (November 2018)
- Record Type:
- Journal Article
- Title:
- The effects of vibro-medical insole on sensation and plantar pressure distribution in diabetic patients with mild-to-moderate peripheral neuropathy. (November 2018)
- Main Title:
- The effects of vibro-medical insole on sensation and plantar pressure distribution in diabetic patients with mild-to-moderate peripheral neuropathy
- Authors:
- Bagherzadeh Cham, Masumeh
Mohseni-Bandpei, Mohammad Ali
Bahramizadeh, Mahmood
Kalbasi, Saeed
Biglarian, Akbar - Abstract:
- Abstract: Background: The first aim of this study was to determine the effect of a vibro-medical insole on pressure sensation and the second was to measure the effects of a vibro-medical insole with and without random noise on plantar pressure distribution in diabetic patients with mild-to-moderate peripheral neuropathy. Methods: Twenty patients with mild-to-moderate diabetic neuropathy were recruited in the clinical trial pre-test, post-test study. A medical insole was made for each participant and a vibratory system was inserted into it. Pressure sensation was evaluated before and after the 30-min walk using the vibro-medical insole with added random noise by Semmes-Weinstein Monofilaments. Peak pressure data was measured before and after 30-min walking with a vibro-medical insole with and without random noise by the Pedar-x system. Findings: Pressure sensations showed improvement after 30-min walking with the vibro-medical insole with added random noise at the heel, metatarsophalangeal heads and hallux of both feet in all participants ( p < 0.05). Peak pressure decreased significantly in the heel, MTP2, 3, MTP4, 5 and hallux ( p < 0.05) and increased in midfoot ( p < 0.05) using the vibro-medical insole with and without random noise compared to the shoe only condition. Only the peak pressure of the heel region decreased using the vibro-medical insole with random noise compared to without random noise ( p = 0.006). Interpretation: Thirty minute walking with aAbstract: Background: The first aim of this study was to determine the effect of a vibro-medical insole on pressure sensation and the second was to measure the effects of a vibro-medical insole with and without random noise on plantar pressure distribution in diabetic patients with mild-to-moderate peripheral neuropathy. Methods: Twenty patients with mild-to-moderate diabetic neuropathy were recruited in the clinical trial pre-test, post-test study. A medical insole was made for each participant and a vibratory system was inserted into it. Pressure sensation was evaluated before and after the 30-min walk using the vibro-medical insole with added random noise by Semmes-Weinstein Monofilaments. Peak pressure data was measured before and after 30-min walking with a vibro-medical insole with and without random noise by the Pedar-x system. Findings: Pressure sensations showed improvement after 30-min walking with the vibro-medical insole with added random noise at the heel, metatarsophalangeal heads and hallux of both feet in all participants ( p < 0.05). Peak pressure decreased significantly in the heel, MTP2, 3, MTP4, 5 and hallux ( p < 0.05) and increased in midfoot ( p < 0.05) using the vibro-medical insole with and without random noise compared to the shoe only condition. Only the peak pressure of the heel region decreased using the vibro-medical insole with random noise compared to without random noise ( p = 0.006). Interpretation: Thirty minute walking with a vibro-medical insole seems to improve pressure sensation and alter peak pressure in diabetic patients with mild-to-moderate peripheral neuropathy. This work suggests that vibro-medical insoles can be used for daily living activities and possibly decreases the risk of ulceration in diabetic neuropathy patients. Highlights: Vibro-medical insole seems to improve pressure sensation in diabetic peripheral neuropathy. Vibro-medical insole seems to alter plantar pressure distribution in diabetic peripheral neuropathy. Vibro-medical insole seems to decrease the risk of ulceration in diabetic peripheral neuropathy. Vibro-medical insole can be used for daily living activities in diabetic peripheral neuropathy. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 59(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 59(2018)
- Issue Display:
- Volume 59, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 2018
- Issue Sort Value:
- 2018-0059-2018-0000
- Page Start:
- 34
- Page End:
- 39
- Publication Date:
- 2018-11
- Subjects:
- SR Stochastic resonance -- TCNS Toronto Clinical Neuropathy Score -- SWM Semmes-Weinstein monofilaments -- MTP Metatarsophalangeal -- VPT Vibration perception threshold
Diabetic neuropathy -- Stochastic resonance -- Plantar pressure distribution -- Plantar sensation
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.08.007 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20831.xml