Zawadzki, Robert J. - Abstract:
- Abstract: For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinalAbstract: For in vivo mouse retinal imaging, especially with Adaptive Optics instruments, application of a contact lens is desirable, as it allows maintenance of cornea hydration and helps to prevent cataract formation during lengthy imaging sessions. However, since the refractive elements of the eye (cornea and lens) serve as the objective for most in vivo retinal imaging systems, the use of a contact lens, even with 0 Dpt. refractive power, can alter the system's optical properties. In this investigation we examined the effective focal length change and the aberrations that arise from use of a contact lens. First, focal length changes were simulated with a Zemax mouse eye model. Then ocular aberrations with and without a 0 Dpt. contact lens were measured with a Shack-Hartmann wavefront sensor (SHWS) in a customized AO-SLO system. Total RMS wavefront errors were measured for two groups of mice (14-month, and 2.5-month-old), decomposed into 66 Zernike aberration terms, and compared. These data revealed that vertical coma and spherical aberrations were increased with use of a contact lens in our system. Based on the ocular wavefront data we evaluated the effect of the contact lens on the imaging system performance as a function of the pupil size. Both RMS error and Strehl ratios were quantified for the two groups of mice, with and without contact lenses, and for different input beam sizes. These results provide information for determining optimum pupil size for retinal imaging without adaptive optics, and raise critical issues for design of mouse optical imaging systems that incorporate contact lenses. Highlights: Contact lens induced changes to mouse ocular aberrations are studied in detail using simulation and experiments. Application of the contact lens increases the effective focal length of the mouse eye and affects system resolution. Contact lens introduce two major aberrations: spherical and vertical coma (if not aligned properly). High spatial and temporal wavefront sensing allows accurate mapping of mouse eye aberrations, enabling photoreceptor imaging. … (more)
- Is Part Of:
- Experimental eye research. Volume 172(2018)
- Journal:
- Experimental eye research
- Issue:
- Volume 172(2018)
- Issue Display:
- Volume 172, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 172
- Issue:
- 2018
- Issue Sort Value:
- 2018-0172-2018-0000
- Page Start:
- 86
- Page End:
- 93
- Publication Date:
- 2018-07
- Subjects:
- Contact lens -- Effective focal length -- Mouse eye aberration -- Adaptive optics -- Scanning laser ophthalmoscope
Ophthalmology -- Periodicals
Eye -- Periodicals
Œil -- Périodiques
Ophthalmology
Periodicals
Electronic journals
612.8405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00144835 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0014-4835;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.exer.2018.03.027 ↗
- Languages:
- English
- ISSNs:
- 0014-4835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20807.xml