Evaluating the primary stability of standard vs lateralised cementless femoral stems – A finite element study using a diverse patient cohort. (November 2018)
- Record Type:
- Journal Article
- Title:
- Evaluating the primary stability of standard vs lateralised cementless femoral stems – A finite element study using a diverse patient cohort. (November 2018)
- Main Title:
- Evaluating the primary stability of standard vs lateralised cementless femoral stems – A finite element study using a diverse patient cohort
- Authors:
- Al-Dirini, Rami M.A.
Martelli, Saulo
Huff, Daniel
Zhang, Ju
Clement, John G.
Besier, Thor
Taylor, Mark - Abstract:
- Abstract: Background: Restoring the original femoral offset is desirable for total hip replacements as it preserves the original muscle lever arm and soft tissue tensions. This can be achieved through lateralised stems, however, the effect of variation in the hip centre offset on the primary stability remains unclear. Methods: Finite element analysis was used to compare the primary stability of lateralised and standard designs for a cementless femoral stem (Corail®) across a representative cohort of male and female femora ( N = 31 femora; age from 50 to 80 years old). Each femur model was implanted with three designs of the Corail® stem, each designed to achieve a different degree of lateralisation. An automated algorithm was used to select the size and position that achieve maximum metaphyseal fit for each of the designs. Joint contact and muscle forces simulating the peak forces during level gait and stair climbing were scaled to the body mass of each subject. Findings: The study found that differences in restoring the native femoral offset introduce marginal differences in micromotion (differences in peak micromotion <21 μm), for most cases. Nonetheless, significant reduction in the interfacial strains (>3000 με) was achieved for some subjects when lateralized stems were used. Interpretation: Findings of this study suggest that, with the appropriate size and alignment, the standard offset design is likely to be sufficient for primary stability, in most cases.Abstract: Background: Restoring the original femoral offset is desirable for total hip replacements as it preserves the original muscle lever arm and soft tissue tensions. This can be achieved through lateralised stems, however, the effect of variation in the hip centre offset on the primary stability remains unclear. Methods: Finite element analysis was used to compare the primary stability of lateralised and standard designs for a cementless femoral stem (Corail®) across a representative cohort of male and female femora ( N = 31 femora; age from 50 to 80 years old). Each femur model was implanted with three designs of the Corail® stem, each designed to achieve a different degree of lateralisation. An automated algorithm was used to select the size and position that achieve maximum metaphyseal fit for each of the designs. Joint contact and muscle forces simulating the peak forces during level gait and stair climbing were scaled to the body mass of each subject. Findings: The study found that differences in restoring the native femoral offset introduce marginal differences in micromotion (differences in peak micromotion <21 μm), for most cases. Nonetheless, significant reduction in the interfacial strains (>3000 με) was achieved for some subjects when lateralized stems were used. Interpretation: Findings of this study suggest that, with the appropriate size and alignment, the standard offset design is likely to be sufficient for primary stability, in most cases. Nonetheless, appropriate use of lateralised stems has the potential reduce the risk of peri-prosthetic bone damage. This highlights the importance of appropriate implant selection during the surgical planning stage. Highlights: For most cases, the standard offset design is likely to be sufficient for primary stability. Appropriate use of lateralised stems can reduce the risk of peri-prosthetic bone damage. Appropriate implant selection during the surgical planning stage is essential. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 59(2018)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 59(2018)
- Issue Display:
- Volume 59, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 2018
- Issue Sort Value:
- 2018-0059-2018-0000
- Page Start:
- 101
- Page End:
- 109
- Publication Date:
- 2018-11
- Subjects:
- Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.09.002 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20776.xml