Performance evaluation of flexible CIGS modules based on operational data under outdoor conditions. Issue 2 (24th December 2021)
- Record Type:
- Journal Article
- Title:
- Performance evaluation of flexible CIGS modules based on operational data under outdoor conditions. Issue 2 (24th December 2021)
- Main Title:
- Performance evaluation of flexible CIGS modules based on operational data under outdoor conditions
- Authors:
- Lee, Ruda
Lee, Hyomun
Kim, Dongsu
Yoon, Jongho - Abstract:
- Abstract: As a major driver to achieve feasible long‐term goals of the Korean Green New Deal policy, a renewable system application in a building, such as the building‐integrated photovoltaics (BIPV) system, has been expedited by raising a BIPV installation subsidy to 70%. Among the technology of BIPV modules, the CuInGaSe2 (CIGS) type module has been drawing attention and considered as one of the effective alternatives because of its benefits, including its flexibility, lightweights, and relative ease to use as a building material. However, the lack of information understanding of its real application to buildings has still existed under various outdoor experimental conditions. In response to this gap, this study analyzed the power generation performance of flexible CIGS modules under outdoor exposure conditions to evaluate their applicability to BIPV buildings. To conduct the test, the CIGS module was installed on an inclined plane (30°) and vertical plane (90°) using a mock‐up installed facing the south. In particular, this study assessed performance ratio (PR) values to analyze the power generation performance behaviors under direct/diffuse irradiance conditions along with diverse cloud cover conditions. Results from this experimental case study indicated that the power generation performance of the vertical CIGS module decreased compared with that of the inclined CIGS module during all analysis periods, except for the February period. This phenomenon became moreAbstract: As a major driver to achieve feasible long‐term goals of the Korean Green New Deal policy, a renewable system application in a building, such as the building‐integrated photovoltaics (BIPV) system, has been expedited by raising a BIPV installation subsidy to 70%. Among the technology of BIPV modules, the CuInGaSe2 (CIGS) type module has been drawing attention and considered as one of the effective alternatives because of its benefits, including its flexibility, lightweights, and relative ease to use as a building material. However, the lack of information understanding of its real application to buildings has still existed under various outdoor experimental conditions. In response to this gap, this study analyzed the power generation performance of flexible CIGS modules under outdoor exposure conditions to evaluate their applicability to BIPV buildings. To conduct the test, the CIGS module was installed on an inclined plane (30°) and vertical plane (90°) using a mock‐up installed facing the south. In particular, this study assessed performance ratio (PR) values to analyze the power generation performance behaviors under direct/diffuse irradiance conditions along with diverse cloud cover conditions. Results from this experimental case study indicated that the power generation performance of the vertical CIGS module decreased compared with that of the inclined CIGS module during all analysis periods, except for the February period. This phenomenon became more distinct as the solar altitude angle increased, and the power generation performance of the vertical module became similar to that of the inclined module as the altitude angle decreased. By experimenting with the diffuse irradiance condition depending on the change in cloud cover, the PR decreased by approximately 12%. Abstract : This study analyzed the power generation performance of flexible CIGS modules under outdoor exposure conditions to evaluate their applicability to BIPV buildings. To conduct the test, the CIGS module was installed on an inclined plane (30°) and vertical plane (90°) using a mock‐up installed facing the south. In particular, this study assessed performance ratio (PR) values to analyze the power generation performance behaviors under direct/diffuse irradiance conditions along with diverse cloud cover conditions. … (more)
- Is Part Of:
- Energy science & engineering. Volume 10:Issue 2(2022)
- Journal:
- Energy science & engineering
- Issue:
- Volume 10:Issue 2(2022)
- Issue Display:
- Volume 10, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2022-0010-0002-0000
- Page Start:
- 292
- Page End:
- 307
- Publication Date:
- 2021-12-24
- Subjects:
- building‐integrated photovoltaics (BIPV) -- CuInGaSe2 (CIGS) -- performance ratio -- solar altitude angle
Energy industries -- Periodicals
Energy development -- Periodicals
Power resources -- Periodicals
621.042 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2050-0505 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ese3.1040 ↗
- Languages:
- English
- ISSNs:
- 2050-0505
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20777.xml