Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up. (11th November 2021)
- Record Type:
- Journal Article
- Title:
- Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up. (11th November 2021)
- Main Title:
- Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up
- Authors:
- El-Chami, Mikhael F
Bockstedt, Lindsay
Longacre, Colleen
Higuera, Lucas
Stromberg, Kurt
Crossley, George
Kowal, Robert C
Piccini, Jonathan P - Abstract:
- Abstract: Aims : Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. Methods and results : The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data ( n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims ( n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45–0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60–0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 yearsAbstract: Aims : Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. Methods and results : The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data ( n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims ( n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45–0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60–0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91–1.04, P = 0.37). Conclusion : In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years. Graphical Abstract: … (more)
- Is Part Of:
- European heart journal. Volume 43:Number 12(2022)
- Journal:
- European heart journal
- Issue:
- Volume 43:Number 12(2022)
- Issue Display:
- Volume 43, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 43
- Issue:
- 12
- Issue Sort Value:
- 2022-0043-0012-0000
- Page Start:
- 1207
- Page End:
- 1215
- Publication Date:
- 2021-11-11
- Subjects:
- Leadless pacemakers -- Transvenous pacemakers -- System reintervention -- Complications -- Survival
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab767 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20779.xml