Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes. Issue 1 (January 2022)
- Record Type:
- Journal Article
- Title:
- Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes. Issue 1 (January 2022)
- Main Title:
- Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes
- Authors:
- Henriquez, Maria A.
Gomez, Isabel
Camino-Quezada, Maythe
Izquierdo, Luis
Chauca, José
Binder, Perry S. - Abstract:
- Abstract : Purpose: To assess the repeatability of corneal dynamic response (CDR) parameters in normal and keratoconus (KC) eyes using ultra high-speed Scheimpflug imaging. Methods: Prospective, comparative, observational study, including eyes of 112 patients that underwent high-speed Scheimpflug imaging analysis (Corvis ST, OCULUS). Twenty-one CDR parameters were evaluated to asses repeatability using: coefficient of repeatability (CR), coefficient of variation, intraclass correlation coefficient (ICC) and within-subject SD. Three consecutive measurements by the same operator were performed for each eye. Results: There were no significant differences between the three consecutive measurements for all parameters in both normal and KC eyes. 71.42% (15 of the 21 parameters evaluated) and 85.71% (18 of the 21 parameters) were highly repeatable in the normal and KC group, respectively. The tomographic biomechanical index (TBI), corneal biomechanical index (CBI), and stiffness parameter (SPA1) showed an ICC of 0.978, 0.954, and 0.958 in normal and 0.982, 0.892, and 0.978 in KC eyes, respectively. The CR in normal eyes for TBI, CBI, and SPA1 were 0.169, 0.242, and 14.12, respectively, and for KC eyes 0.06, 0.23, and 13.64, respectively. Conclusions: Most of the corneal dynamic response parameters were highly repeatable in normal and KC eyes.
- Is Part Of:
- Eye & contact lens. Volume 48:Issue 1(2022)
- Journal:
- Eye & contact lens
- Issue:
- Volume 48:Issue 1(2022)
- Issue Display:
- Volume 48, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 1
- Issue Sort Value:
- 2022-0048-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- Keratoconus -- Corneal dynamic response -- Scheimpflug imaging -- Repeatability -- corvis -- corneal biomechanics
Contact lenses -- Periodicals
Intraocular lenses -- Periodicals
Orthokeratology -- Periodicals
Anterior segment (Eye) -- Diseases -- Periodicals
617.7523 - Journal URLs:
- http://journals.lww.com/claojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/ICL.0000000000000845 ↗
- Languages:
- English
- ISSNs:
- 1542-2321
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3854.587000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20760.xml