Blink detection and magnetic force generation for correction of lagophthalmos, with specific regard to implant compatibility testing. (2nd January 2022)
- Record Type:
- Journal Article
- Title:
- Blink detection and magnetic force generation for correction of lagophthalmos, with specific regard to implant compatibility testing. (2nd January 2022)
- Main Title:
- Blink detection and magnetic force generation for correction of lagophthalmos, with specific regard to implant compatibility testing
- Authors:
- Coussa, Razek Georges
Lomis, Nikita
Antaki, Fares
Samle, Jason
Patel, Kavita
Christodoulou, George
Prakash, Satya
Oestreicher, James
Arthurs, Bryan - Abstract:
- ABSTRACT: Purpose: The overall goal was to restore a normal and synchronous blink in unilateral lagophthalmos. We describe the biocompatibility profiling of a novel ferromagnetic implant used for electromagnetic eyelid force generation. Methods: A non-contact blink detection system and an electromagnetic stimulation system were designed and tested. A modified Lester-Burch speculum equipped with strain gauge technology was used in blinking force measurement. Samarium–cobalt magnets were prototyped and coated with parylene-C. Biocompatibility testing was performed using NIH/3T3 mouse fibroblast cells with MTT colorimetric assay cytotoxic quantification. Outcome Measures: Cellular viability and interleukin concentrations. Results: Our system was capable of detecting 95.5 ± 3.6% of blinks in various lighting conditions. Using our force measuring device, the difference between non-paralyzed and paralyzed orbicularis oculi (OO) for normal and forceful blinking closure was 40.4 g and 101.9 g, respectively. A 16.6 × 5.0 × 1.5 mm curved shaped samarium cobalt eyelid implant was successfully developed and showed a reproducible blink at 100 ms with full corneal coverage with external eyelid taping. Compared to gold weights, parylene-C coated samarium cobalt implants showed not only excellent cell viability (82.0 ± 4.9% vs. 88.4 ± 0.9%, respectively, p > .05), but also below detection threshold for pro-inflammatory marker concentrations (interleukin-6 < 2 pg/mL andABSTRACT: Purpose: The overall goal was to restore a normal and synchronous blink in unilateral lagophthalmos. We describe the biocompatibility profiling of a novel ferromagnetic implant used for electromagnetic eyelid force generation. Methods: A non-contact blink detection system and an electromagnetic stimulation system were designed and tested. A modified Lester-Burch speculum equipped with strain gauge technology was used in blinking force measurement. Samarium–cobalt magnets were prototyped and coated with parylene-C. Biocompatibility testing was performed using NIH/3T3 mouse fibroblast cells with MTT colorimetric assay cytotoxic quantification. Outcome Measures: Cellular viability and interleukin concentrations. Results: Our system was capable of detecting 95.5 ± 3.6% of blinks in various lighting conditions. Using our force measuring device, the difference between non-paralyzed and paralyzed orbicularis oculi (OO) for normal and forceful blinking closure was 40.4 g and 101.9 g, respectively. A 16.6 × 5.0 × 1.5 mm curved shaped samarium cobalt eyelid implant was successfully developed and showed a reproducible blink at 100 ms with full corneal coverage with external eyelid taping. Compared to gold weights, parylene-C coated samarium cobalt implants showed not only excellent cell viability (82.0 ± 4.9% vs. 88.4 ± 0.9%, respectively, p > .05), but also below detection threshold for pro-inflammatory marker concentrations (interleukin-6 < 2 pg/mL and interleukin-10 < 3 pg/mL). Conclusions: We demonstrated excellent in-vitro biocompatibility of our parylene-C coated samarium cobalt implants. We believe that our novel approach can improve the quality-of-life of affected individuals and provides new understanding of blinking biomechanics. … (more)
- Is Part Of:
- Orbit. Volume 41:Number 1(2022)
- Journal:
- Orbit
- Issue:
- Volume 41:Number 1(2022)
- Issue Display:
- Volume 41, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2022-0041-0001-0000
- Page Start:
- 59
- Page End:
- 68
- Publication Date:
- 2022-01-02
- Subjects:
- Blinking detection -- blink stimulation -- implant biocompatibility -- lagophthalmos
Eye-sockets -- Surgery -- Periodicals
Eye-sockets -- Diseases -- Periodicals
Orbit -- surgery -- Periodicals
Orbital Diseases -- Periodicals
617.7 - Journal URLs:
- http://informahealthcare.com/loi/orb ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/01676830.asp ↗ - DOI:
- 10.1080/01676830.2020.1826544 ↗
- Languages:
- English
- ISSNs:
- 0167-6830
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6277.869600
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20771.xml