Diagnostic accuracy of teleretinal screening for detection of diabetic retinopathy and age-related macular degeneration: a systematic review and meta-analysis. Issue 1 (10th February 2022)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of teleretinal screening for detection of diabetic retinopathy and age-related macular degeneration: a systematic review and meta-analysis. Issue 1 (10th February 2022)
- Main Title:
- Diagnostic accuracy of teleretinal screening for detection of diabetic retinopathy and age-related macular degeneration: a systematic review and meta-analysis
- Authors:
- Mehraban Far, Parsa
Tai, Felicia
Ogunbameru, Adeteju
Pechlivanoglou, Petros
Sander, Beate
Wong, David T
Brent, Michael H
Felfeli, Tina - Abstract:
- Abstract : Objective: To evaluate the diagnostic accuracy of teleretinal screening compared with face-to-face examination for detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD). Methods and analysis: This study adhered to the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA). A comprehensive search of OVID MEDLINE, EMBASE and Cochrane CENTRAL was performed from January 2010 to July 2021. QUADAS-2 tool was used to assess methodological quality and applicability of the studies. A bivariate random effects model was used to perform the meta-analysis. Referrable DR was defined as any disease severity equal to or worse than moderate non-proliferative DR or diabetic macular oedema (DMO). Results: 28 articles were included. Teleretinal screening achieved a sensitivity of 0.91 (95% CI: 0.82 to 0.96) and specificity of 0.88 (0.74 to 0.95) for any DR (13 studies, n=7207, Grading of Recommendations, Assessment, Development and Evaluation (GRADE) low). Accuracy for referrable DR (10 studies, n=6373, GRADE moderate) was lower with a sensitivity of 0.88 (0.81 to 0.93) and specificity of 0.86 (0.79 to 0.90). After exclusion of ungradable images, the specificity for referrable DR increased to 0.95 (0.90 to 0.98), while the sensitivity remained nearly unchanged at 0.85 (0.76 to 0.91). Teleretinal screening achieved a sensitivity of 0.71 (0.49 to 0.86) and specificity of 0.88 (0.85 to 0.90) forAbstract : Objective: To evaluate the diagnostic accuracy of teleretinal screening compared with face-to-face examination for detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD). Methods and analysis: This study adhered to the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA). A comprehensive search of OVID MEDLINE, EMBASE and Cochrane CENTRAL was performed from January 2010 to July 2021. QUADAS-2 tool was used to assess methodological quality and applicability of the studies. A bivariate random effects model was used to perform the meta-analysis. Referrable DR was defined as any disease severity equal to or worse than moderate non-proliferative DR or diabetic macular oedema (DMO). Results: 28 articles were included. Teleretinal screening achieved a sensitivity of 0.91 (95% CI: 0.82 to 0.96) and specificity of 0.88 (0.74 to 0.95) for any DR (13 studies, n=7207, Grading of Recommendations, Assessment, Development and Evaluation (GRADE) low). Accuracy for referrable DR (10 studies, n=6373, GRADE moderate) was lower with a sensitivity of 0.88 (0.81 to 0.93) and specificity of 0.86 (0.79 to 0.90). After exclusion of ungradable images, the specificity for referrable DR increased to 0.95 (0.90 to 0.98), while the sensitivity remained nearly unchanged at 0.85 (0.76 to 0.91). Teleretinal screening achieved a sensitivity of 0.71 (0.49 to 0.86) and specificity of 0.88 (0.85 to 0.90) for detection of AMD (three studies, n=697, GRADE low). Conclusion: Teleretinal screening is highly accurate for detecting any DR and DR warranting referral. Data for AMD screening is promising but warrants further investigation. PROSPERO registration number: CRD42020191994. … (more)
- Is Part Of:
- BMJ open ophthalmology. Volume 7:Issue 1(2022)
- Journal:
- BMJ open ophthalmology
- Issue:
- Volume 7:Issue 1(2022)
- Issue Display:
- Volume 7, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2022-0007-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-10
- Subjects:
- diagnostic tests/investigation -- retina -- angiogenesis
Ophthalmology -- Periodicals
617.7005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjophth.bmj.com/ ↗ - DOI:
- 10.1136/bmjophth-2021-000915 ↗
- Languages:
- English
- ISSNs:
- 2397-3269
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20762.xml