Influence of electrode to cochlear duct length ratio on post-operative speech understanding outcomes. (4th March 2022)
- Record Type:
- Journal Article
- Title:
- Influence of electrode to cochlear duct length ratio on post-operative speech understanding outcomes. (4th March 2022)
- Main Title:
- Influence of electrode to cochlear duct length ratio on post-operative speech understanding outcomes
- Authors:
- Cooperman, Shayna P.
Aaron, Ksenia A.
Fouad, Ayman
Tran, Emma
Blevins, Nikolas H.
Fitzgerald, Matthew B. - Abstract:
- Abstract : Objective: To assess whether the pre-operative electrode to cochlear duct length ratio (ECDLR), is associated with post-operative speech recognition outcomes. Study Design: A retrospective chart review study. Setting: Tertiary referral center. Patients: The study included sixty-one adult CI recipients with a pre-operative computed tomography scan and a speech recognition test 12 months after implantation. Interventions: The average of two raters' cochlear duct length (CDL) measurements and the length of the recipient's cochlear implant electrode array formed the basis for the electrode-to-cochlear duct length ratio (ECLDR). Speech recognition tests were compared as a function of ECDLR and electrode array length itself. Main outcome measures: The relationship between ECDLR and percent correct on speech recognition tests. Results: A second order polynomial regression relating ECDLR to percent correct on the CNC words speech recognition test was statistically significant, as was a fourth order polynomial regression for the AzBio Quiet test. In contrast, there was no statistically significant relationship between speech recognition scores and electrode array length. Conclusions: ECDLR values can be statistically associated to speech-recognition outcomes. However, these ECDLR values cannot be predicted by the electrode length alone, and must include a measure of CDL.
- Is Part Of:
- Cochlear implants international. Volume 23:Number 2(2022)
- Journal:
- Cochlear implants international
- Issue:
- Volume 23:Number 2(2022)
- Issue Display:
- Volume 23, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2022-0023-0002-0000
- Page Start:
- 59
- Page End:
- 69
- Publication Date:
- 2022-03-04
- Subjects:
- Cochlear implant -- OTOPLAN® -- Med-El -- Electrode Array -- Electrode Insertion -- Speech Recognition
Cochlear implants -- Periodicals
617.882 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1556-9152 ↗
http://www.ingenta.com/journals/browse/whurr/cii ↗
http://www.ingentaconnect.com/content/maney/cii ↗
http://www.tandfonline.com/loi/ycii20 ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1080/14670100.2021.1979289 ↗
- Languages:
- English
- ISSNs:
- 1467-0100
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3292.724200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20754.xml