Right transradial coronary angiography in the setting of tortuous brachiocephalic/thoracic aorta ("elephant head"): Impact on fluoroscopy time and contrast use. Issue 2 (25th January 2021)
- Record Type:
- Journal Article
- Title:
- Right transradial coronary angiography in the setting of tortuous brachiocephalic/thoracic aorta ("elephant head"): Impact on fluoroscopy time and contrast use. Issue 2 (25th January 2021)
- Main Title:
- Right transradial coronary angiography in the setting of tortuous brachiocephalic/thoracic aorta ("elephant head"): Impact on fluoroscopy time and contrast use
- Authors:
- Case, Brian C.
Yerasi, Charan
Forrestal, Brian J.
Chezar‐Azerrad, Chava
Khan, Jaffar M.
Khalid, Nauman
Shlofmitz, Evan
Chen, Yuefeng
Musallam, Anees
Waksman, Ron
Hashim, Hayder - Abstract:
- Abstract: Objectives: Assess the impact on fluoroscopy time and contrast use in patients with tortuous brachiocephalic/thoracic aortas undergoing right transradial coronary angiography (RTCA) and provide strategies to manage. Background: Unfavorable anatomy with severe brachiocephalic/thoracic tortuosity, referred to as an "elephant head, " remains a significant obstacle for RTCA. Methods: We reviewed the coronary angiograms of patients who underwent RTCA and had tortuous aortas. Angiography was attempted first using a universal catheter (Tiger) and switched to a left coronary specific catheter (Judkins Left [JL]) if challenging. Fluoroscopy time, contrast volume, and greatest distance from the patient's midline to the catheter in the aorta were recorded. Results: Forty‐nine patients (62.6 ± 12.0 years, 69.4% male) were included. Fifteen (30.6%) patients underwent successful angiography with a Tiger catheter; 34 (69.4%) patients required switching to JL catheter. The average distance of Tiger catheters to the midline of the spine was 0.78 ± 0.41 cm versus 1.28 ± 0.44 cm ( p = .001) in JL catheters. Tiger catheter use resulted in less fluoroscopy time (6.48 ± 4.73 min) and contrast use (58.87 ± 43.53 ml) than in cases switched to JL (13.26 ± 10.76 min [ p = .026]; 86.5 ± 69.95 ml [( p = .017]). Conclusions: For patients undergoing RTCA with significant brachiocephalic/thoracic aorta tortuosity, "elephant head, " a Tiger catheter can be used efficiently for curvatures <1 cmAbstract: Objectives: Assess the impact on fluoroscopy time and contrast use in patients with tortuous brachiocephalic/thoracic aortas undergoing right transradial coronary angiography (RTCA) and provide strategies to manage. Background: Unfavorable anatomy with severe brachiocephalic/thoracic tortuosity, referred to as an "elephant head, " remains a significant obstacle for RTCA. Methods: We reviewed the coronary angiograms of patients who underwent RTCA and had tortuous aortas. Angiography was attempted first using a universal catheter (Tiger) and switched to a left coronary specific catheter (Judkins Left [JL]) if challenging. Fluoroscopy time, contrast volume, and greatest distance from the patient's midline to the catheter in the aorta were recorded. Results: Forty‐nine patients (62.6 ± 12.0 years, 69.4% male) were included. Fifteen (30.6%) patients underwent successful angiography with a Tiger catheter; 34 (69.4%) patients required switching to JL catheter. The average distance of Tiger catheters to the midline of the spine was 0.78 ± 0.41 cm versus 1.28 ± 0.44 cm ( p = .001) in JL catheters. Tiger catheter use resulted in less fluoroscopy time (6.48 ± 4.73 min) and contrast use (58.87 ± 43.53 ml) than in cases switched to JL (13.26 ± 10.76 min [ p = .026]; 86.5 ± 69.95 ml [( p = .017]). Conclusions: For patients undergoing RTCA with significant brachiocephalic/thoracic aorta tortuosity, "elephant head, " a Tiger catheter can be used efficiently for curvatures <1 cm from the middle of the spine. We propose that for curvatures >1 cm, operators should consider immediately switching to a JL catheter. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 99:Issue 2(2022)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 99:Issue 2(2022)
- Issue Display:
- Volume 99, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 99
- Issue:
- 2
- Issue Sort Value:
- 2022-0099-0002-0000
- Page Start:
- 418
- Page End:
- 423
- Publication Date:
- 2021-01-25
- Subjects:
- coronary angiography -- radial approach -- tortuous aorta
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29470 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20728.xml