Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination. (4th March 2022)
- Record Type:
- Journal Article
- Title:
- Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination. (4th March 2022)
- Main Title:
- Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination
- Authors:
- Liu, Jing
Guo, Guo
Kurepa, Dalibor
Volpicelli, Giovanni
Sorantin, Erich
Lovrenski, Jovan
Alonso-Ojembarrena, Almudena
Hsieh, Kai-Sheng
Lodha, Abhay
Yeh, Tsu F.
Jagła, Mateusz
Shah, Heli
Yan, Wei
Hu, Cai-Bao
Zhou, Xiao-Guang
Guo, Rui-Jun
Cao, Hai-Ying
Wang, Yan
Zong, Hai-Feng
Shang, Li-Li
Ma, Hai-Ran
Liu, Ying
Fu, Wei
Shan, Rui-Yan
Qiu, Ru-Xin
Ren, Xiao-Ling
Copetti, Roberto
Rodriguez-Fanjul, Javier
Feletti, Francesco - Abstract:
- Abstract: Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12–14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4–5 cm. (5) Set 1–2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2–3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to getAbstract: Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases. Nevertheless, in the published literatures, the LUS images may display a significant variation in technical execution, while scanning parameters may influence diagnostic accuracy. The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS. As expected, the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US). Consequently, having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs. The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS. Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1) select a high-end equipment with high-frequency linear array transducer (12–14 MHz). (2) Choose preset suitable for lung examination or small organs. (3) Keep the probe perpendicular to the ribs or parallel to the intercostal space. (4) Set the scanning depth at 4–5 cm. (5) Set 1–2 focal zones and adjust them close to the pleural line. (6) Use fundamental frequency with speckle reduction 2–3 or similar techniques. (7) Turn off spatial compounding imaging. (8) Adjust the time-gain compensation to get uniform image from the near-to far-field. … (more)
- Is Part Of:
- Journal of maternal-fetal & neonatal medicine. Volume 35:Number 5(2022)
- Journal:
- Journal of maternal-fetal & neonatal medicine
- Issue:
- Volume 35:Number 5(2022)
- Issue Display:
- Volume 35, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 35
- Issue:
- 5
- Issue Sort Value:
- 2022-0035-0005-0000
- Page Start:
- 1003
- Page End:
- 1016
- Publication Date:
- 2022-03-04
- Subjects:
- Diagnostic image -- intensive care unit -- lung diseases -- lung ultrasound -- newborn
Obstetrics -- Periodicals
Perinatology -- Periodicals
Infants (Newborn) -- Diseases -- Periodicals
Neonatology -- Periodicals
618.2 - Journal URLs:
- http://informahealthcare.com/loi/jmf ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/14767058.2021.1940943 ↗
- Languages:
- English
- ISSNs:
- 1476-7058
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.332000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20754.xml