Sensitivity, Specificity, and Safety of a Novel ESAT6-CFP10 Skin Test for Tuberculosis Infection in China: 2 Randomized, Self-Controlled, Parallel-Group Phase 2b Trials. (22nd May 2021)
- Record Type:
- Journal Article
- Title:
- Sensitivity, Specificity, and Safety of a Novel ESAT6-CFP10 Skin Test for Tuberculosis Infection in China: 2 Randomized, Self-Controlled, Parallel-Group Phase 2b Trials. (22nd May 2021)
- Main Title:
- Sensitivity, Specificity, and Safety of a Novel ESAT6-CFP10 Skin Test for Tuberculosis Infection in China: 2 Randomized, Self-Controlled, Parallel-Group Phase 2b Trials
- Authors:
- Xu, Miao
Lu, Wei
Li, Tao
Li, Jingxin
Du, Weixin
Wu, Qi
Liu, Qiao
Yuan, Baodong
Lu, Jinbiao
Ding, Xiaoyan
Li, Feng
Liu, Min
Chen, Baowen
Pu, Jiang
Zhang, Rongping
Xi, Xiuhong
Zhou, Rongguang
Mei, Zaoxian
Du, Ronghui
Tao, Lifeng
Martinez, Leonardo
Lu, Shuihua
Wang, Guozhi
Zhu, Fengcai - Abstract:
- Abstract: Background: Diagnostics to identify tuberculosis infection are limited. We aimed to assess the diagnostic accuracy and safety of ESAT6-CFP10 (EC) skin test for tuberculosis infection in Chinese adults. Methods: We conducted 2 randomized, parallel-group clinical trials in healthy participants and tuberculosis patients. All participants were tested with the T-SPOT.TB test, then received an EC skin test and tuberculin skin test (TST). The diameter of skin indurations and/or redness at injection sites were measured at different time periods. A bacillus Calmette Guerin (BCG) model was established to assess the diagnosis of tuberculosis infection using an EC skin test. Results: In total, 777 healthy participants and 96 tuberculosis patients were allocated to receive EC skin test at 1.0 μg/0.1 mL or 0.5 μg/0.1 mL. The area under the curve was 0.95 (95% confidence interval [CI], .91–.97) for the EC skin test at 1.0 μg/0.1 mL at 24–72 hours. Compared with the T-SPOT.TB test, the EC skin test demonstrated similar sensitivity (87.5, 95% CI, 77.8–97.2 vs 86.5, 95% CI, 79.5–93.4) and specificity (98.9, 95% CI, 96.0–99.9 vs 96.1, 95% CI, 93.5–97.8). Among BCG vaccinated participants, the EC skin test had high consistency with the T-SPOT.TB test (96.3, 95% CI, 92.0–100.0). No serious adverse events related to the EC skin test were observed. Conclusions: The EC skin test demonstrated both high specificity and sensitivity at a dose of 1.0 μg/0.1 mL, comparable to the T-SPOT.TBAbstract: Background: Diagnostics to identify tuberculosis infection are limited. We aimed to assess the diagnostic accuracy and safety of ESAT6-CFP10 (EC) skin test for tuberculosis infection in Chinese adults. Methods: We conducted 2 randomized, parallel-group clinical trials in healthy participants and tuberculosis patients. All participants were tested with the T-SPOT.TB test, then received an EC skin test and tuberculin skin test (TST). The diameter of skin indurations and/or redness at injection sites were measured at different time periods. A bacillus Calmette Guerin (BCG) model was established to assess the diagnosis of tuberculosis infection using an EC skin test. Results: In total, 777 healthy participants and 96 tuberculosis patients were allocated to receive EC skin test at 1.0 μg/0.1 mL or 0.5 μg/0.1 mL. The area under the curve was 0.95 (95% confidence interval [CI], .91–.97) for the EC skin test at 1.0 μg/0.1 mL at 24–72 hours. Compared with the T-SPOT.TB test, the EC skin test demonstrated similar sensitivity (87.5, 95% CI, 77.8–97.2 vs 86.5, 95% CI, 79.5–93.4) and specificity (98.9, 95% CI, 96.0–99.9 vs 96.1, 95% CI, 93.5–97.8). Among BCG vaccinated participants, the EC skin test had high consistency with the T-SPOT.TB test (96.3, 95% CI, 92.0–100.0). No serious adverse events related to the EC skin test were observed. Conclusions: The EC skin test demonstrated both high specificity and sensitivity at a dose of 1.0 μg/0.1 mL, comparable to the T-SPOT.TB test. The diagnostic accuracy of the EC skin test was not impacted by BCG vaccination. Clinical Trials Registration: NCT02389322 and NCT02336542. Abstract : Current diagnostics for tuberculosis infection are limited. We evaluated the ESAT6-CFP10 skin test and found a good safety profile and high diagnostic accuracy. It may be a viable option, especially in low-income countries with universal bacillus Calmette Guerin vaccination. … (more)
- Is Part Of:
- Clinical infectious diseases. Volume 74:Number 4(2022)
- Journal:
- Clinical infectious diseases
- Issue:
- Volume 74:Number 4(2022)
- Issue Display:
- Volume 74, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 74
- Issue:
- 4
- Issue Sort Value:
- 2022-0074-0004-0000
- Page Start:
- 668
- Page End:
- 677
- Publication Date:
- 2021-05-22
- Subjects:
- tuberculosis -- ESAT6-CFP10 -- tuberculosis infection -- diagnostics
Communicable diseases -- Periodicals
616.905 - Journal URLs:
- http://cid.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗
http://www.journals.uchicago.edu/CID/journal ↗
http://www.jstor.org/journals/10584838.html ↗ - DOI:
- 10.1093/cid/ciab472 ↗
- Languages:
- English
- ISSNs:
- 1058-4838
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293860
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20752.xml