A case report of intracardiac bone cement embolization after posterior decompression and cement-enhanced pedicle screw fixation for osteoporosis and lumbar degeneration. Issue 8 (25th February 2022)
- Record Type:
- Journal Article
- Title:
- A case report of intracardiac bone cement embolization after posterior decompression and cement-enhanced pedicle screw fixation for osteoporosis and lumbar degeneration. Issue 8 (25th February 2022)
- Main Title:
- A case report of intracardiac bone cement embolization after posterior decompression and cement-enhanced pedicle screw fixation for osteoporosis and lumbar degeneration
- Authors:
- Sun, Kui
Huang, Fuli
Liang, Biru - Editors:
- Saranathan., Maya
- Abstract:
- Abstract: Rationale: Bone cement leakage is a common complication of percutaneous kyphoplasty (PKP) and percutaneous vertebroplasty (PVP) surgery and has also been reported in posterior decompression and cement-enhanced pedicle screw fixation. When bone cement leaks through the venous system, it will have serious consequences and even endanger the life of the patient, especially when the bone cement causes intracardiac embolism. Patient concerns: A 70-year-old woman developed chest tightness and decreased blood oxygen saturation following posterior decompression and cement-enhanced pedicle screw fixation. Diagnosis: After the patient was given symptomatic treatment, the symptoms were not relieved, the high-sensitivity troponin I level continued to rise, the electrocardiogram results were abnormal, and chest computed tomography (CT) revealed multiple flaky and strip-shaped dense shadows in the heart. Intervention: The patient underwent removal of foreign bodies from the heart under cardiopulmonary bypass and tricuspid valvuloplasty, removal of intracardiac bone cement, and repair of the tricuspid valve and chordae. Outcome: The patient recovered well postoperatively and was discharged from the hospital after 3 weeks. There were no intracardiac foreign bodies observed on chest CT after the operation. Lessons: For patients with cardiopulmonary discomfort after posterior decompression and bone cement-enhanced pedicle screw fixation, in view of the limitations of radiographicAbstract: Rationale: Bone cement leakage is a common complication of percutaneous kyphoplasty (PKP) and percutaneous vertebroplasty (PVP) surgery and has also been reported in posterior decompression and cement-enhanced pedicle screw fixation. When bone cement leaks through the venous system, it will have serious consequences and even endanger the life of the patient, especially when the bone cement causes intracardiac embolism. Patient concerns: A 70-year-old woman developed chest tightness and decreased blood oxygen saturation following posterior decompression and cement-enhanced pedicle screw fixation. Diagnosis: After the patient was given symptomatic treatment, the symptoms were not relieved, the high-sensitivity troponin I level continued to rise, the electrocardiogram results were abnormal, and chest computed tomography (CT) revealed multiple flaky and strip-shaped dense shadows in the heart. Intervention: The patient underwent removal of foreign bodies from the heart under cardiopulmonary bypass and tricuspid valvuloplasty, removal of intracardiac bone cement, and repair of the tricuspid valve and chordae. Outcome: The patient recovered well postoperatively and was discharged from the hospital after 3 weeks. There were no intracardiac foreign bodies observed on chest CT after the operation. Lessons: For patients with cardiopulmonary discomfort after posterior decompression and bone cement-enhanced pedicle screw fixation, in view of the limitations of radiographic examination, we recommend performing chest CT examination to confirm the diagnosis. For patients with intravascular foreign body embolism, multidisciplinary team joint treatment saves lives. … (more)
- Is Part Of:
- Medicine. Volume 101:Issue 8(2022)
- Journal:
- Medicine
- Issue:
- Volume 101:Issue 8(2022)
- Issue Display:
- Volume 101, Issue 8 (2022)
- Year:
- 2022
- Volume:
- 101
- Issue:
- 8
- Issue Sort Value:
- 2022-0101-0008-0000
- Page Start:
- e28826
- Page End:
- Publication Date:
- 2022-02-25
- Subjects:
- bone cement leakage -- bone cement-enhanced pedicle screw fixation -- intracardiac embolism -- osteoporosis
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000028826 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20753.xml