Improved Performance of Compartments in Detecting the Activity of Axial Spondyloarthritis Based on IVIM DWI with Optimized Threshold b Value. (10th January 2022)
- Record Type:
- Journal Article
- Title:
- Improved Performance of Compartments in Detecting the Activity of Axial Spondyloarthritis Based on IVIM DWI with Optimized Threshold b Value. (10th January 2022)
- Main Title:
- Improved Performance of Compartments in Detecting the Activity of Axial Spondyloarthritis Based on IVIM DWI with Optimized Threshold b Value
- Authors:
- Ye, Qiang
Xie, Zhuoyao
Guo, Chang
Lu, Xing
Zheng, Kai
Zhao, Yinghua - Other Names:
- Roldan-Valadez Ernesto Academic Editor.
- Abstract:
- Abstract : Purpose . To explore the diagnostic performance of the optimized threshold b values on IVIM to detect the activity in axial spondyloarthritis (axSpA) patients. Method . 40 axSpA patients in the active group, 144 axSpA patients in the inactive group, and 20 healthy volunteers were used to evaluate the tissue diffusion coefficient (D slow ), perfusion fraction (f ), and pseudodiffusion coefficient (D fast ) with b thresholds of 10, 20, and 30 s/mm 2 . The Kruskal-Wallis test and one way ANOVA test was used to compare the different activity among the three groups in axSpA patients, and receiver operating characteristic (ROC) curve analysis was applied to evaluate the performance for D slow, f, and D fast to detect the activity in axSpA patients, respectively. Results . D slow demonstrated a statistical difference between two groups (P < 0.05 ) with all threshold b values. With the threshold b value of 30 s/mm 2, f could discriminate the active from control groups (P < 0.05 ). D slow had similar performance between the active and the inactive groups with threshold b values of 10, 20, and 30 s/mm 2 (AUC: 0.877, 0.882, and 0.881, respectively, all P < 0.017 ). Using the optimized threshold b value of 30 s/mm 2, f showed the best performance to separate the active from the inactive and the control groups with AUC of 0.613 and 0.738 (both P < 0.017 ) among all threshold b values. Conclusion. D slow and f exhibited increased diagnostic performance using the optimizedAbstract : Purpose . To explore the diagnostic performance of the optimized threshold b values on IVIM to detect the activity in axial spondyloarthritis (axSpA) patients. Method . 40 axSpA patients in the active group, 144 axSpA patients in the inactive group, and 20 healthy volunteers were used to evaluate the tissue diffusion coefficient (D slow ), perfusion fraction (f ), and pseudodiffusion coefficient (D fast ) with b thresholds of 10, 20, and 30 s/mm 2 . The Kruskal-Wallis test and one way ANOVA test was used to compare the different activity among the three groups in axSpA patients, and receiver operating characteristic (ROC) curve analysis was applied to evaluate the performance for D slow, f, and D fast to detect the activity in axSpA patients, respectively. Results . D slow demonstrated a statistical difference between two groups (P < 0.05 ) with all threshold b values. With the threshold b value of 30 s/mm 2, f could discriminate the active from control groups (P < 0.05 ). D slow had similar performance between the active and the inactive groups with threshold b values of 10, 20, and 30 s/mm 2 (AUC: 0.877, 0.882, and 0.881, respectively, all P < 0.017 ). Using the optimized threshold b value of 30 s/mm 2, f showed the best performance to separate the active from the inactive and the control groups with AUC of 0.613 and 0.738 (both P < 0.017 ) among all threshold b values. Conclusion. D slow and f exhibited increased diagnostic performance using the optimized threshold b value of 30 s/mm 2 compared with 10 and 20 s/mm 2, whereas D fast did not. … (more)
- Is Part Of:
- BioMed research international. Volume 2022(2022)
- Journal:
- BioMed research international
- Issue:
- Volume 2022(2022)
- Issue Display:
- Volume 2022, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 2022
- Issue:
- 2022
- Issue Sort Value:
- 2022-2022-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01-10
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2022/2276102 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 20714.xml