Comparison of time taken to obtain an arterial blood gas result at the bedside using the ProximaTM point of care machine vs. a standard remote arterial blood gas analyser: A randomized controlled trial. (May 2022)
- Record Type:
- Journal Article
- Title:
- Comparison of time taken to obtain an arterial blood gas result at the bedside using the ProximaTM point of care machine vs. a standard remote arterial blood gas analyser: A randomized controlled trial. (May 2022)
- Main Title:
- Comparison of time taken to obtain an arterial blood gas result at the bedside using the ProximaTM point of care machine vs. a standard remote arterial blood gas analyser: A randomized controlled trial
- Authors:
- Mitchell, Kay
Salmon, Karen E
Egbosimba, David
Troughton, Gavin
Grocott, Mike PW - Abstract:
- Introduction: The Proxima TM point of care (POC) device enables arterial blood gas (ABG) samples to be analysed without the nurse leaving the patient. The benefits of this for work efficiency have not been evaluated. Methods: We compared the time taken to obtain an ABG result using Proxima TM versus a standard ABG sampling system. Twenty patients were randomized to ABG sampling using Proxima TM, or a standard ABG system. Nurses were observed performing all ABG sampling episodes for a minimum of 24 hours and no more than 72 hours. Results: The mean time taken to obtain a result using Proxima TM was 4:56 (SD = 1:40) minutes compared to 6:31 (SD = 1:53) minutes for the standard ABG technique (p < 0.001). Mean time away from the patient's bedside was 3.07 (SD = 1:17) minutes using the standard system and 0 minutes using Proxima TM (p < 0.001). Conclusions: Reduced time for blood gas sampling and avoidance of time away from patients may have significant patient safety and resource management implications, but the clinical and financial significance were not evaluated.
- Is Part Of:
- Journal of the Intensive Care Society. Volume 23:Number 2(2022)
- Journal:
- Journal of the Intensive Care Society
- Issue:
- Volume 23:Number 2(2022)
- Issue Display:
- Volume 23, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2022-0023-0002-0000
- Page Start:
- 95
- Page End:
- 102
- Publication Date:
- 2022-05
- Subjects:
- Blood specimen collection -- time and motion studies -- point of care technology -- critical care
Critical care medicine -- Periodicals
Intensive care units -- Periodicals
616.028 - Journal URLs:
- http://www.uk.sagepub.com/journals/Journal202320 ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1751143720973847 ↗
- Languages:
- English
- ISSNs:
- 1751-1437
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20709.xml