Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy. Issue 2 (2nd September 2021)
- Record Type:
- Journal Article
- Title:
- Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy. Issue 2 (2nd September 2021)
- Main Title:
- Comparing clinical performance of current implantable cardioverter-defibrillator implantation recommendations in arrhythmogenic right ventricular cardiomyopathy
- Authors:
- Bosman, Laurens P
Nielsen Gerlach, Claire L
Cadrin-Tourigny, Julia
Orgeron, Gabriela
Tichnell, Crystal
Murray, Brittney
Bourfiss, Mimount
van der Heijden, Jeroen F
Yap, Sing-Chien
Zeppenfeld, Katja
van den Berg, Maarten P
Wilde, Arthur A M
Asselbergs, Folkert W
Tandri, Hariskrishna
Calkins, Hugh
van Tintelen, J Peter
James, Cynthia A
te Riele, Anneline S J M - Abstract:
- Abstract: Aims: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms in ARVC. Methods and results: We classified 617 definite ARVC patients (38.5 ± 15.1 years, 52.4% male, 39.2% prior sustained VA) according to four algorithms. Clinical performance was evaluated by sensitivity, specificity, ROC-analysis, and decision curve analysis for any sustained VA and for fast VA (>250 b.p.m.). During 6.4 [2.8–11.5] years follow-up, 282 (45.7%) patients experienced any sustained VA, and 63 (10.2%) fast VA. For any sustained VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (94.0–97.8% vs. 76.7–83.5%), but lower specificity (15.9–32.0% vs. 42.7%-60.1%). Similarly, for fast VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (95.2–97.1% vs. 76.7–78.4%) but lower specificity (42.7–43.1 vs. 76.7–78.4%). Decision curve analysis showed ITFC and mITFC to be superior for a 5-year sustained VA risk ICD indication threshold between 5–25% or 2–9% for fast VA. Conclusion: The ITFC and mITFC provide the highest protection rates, whereas AHA and HRSAbstract: Aims: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms in ARVC. Methods and results: We classified 617 definite ARVC patients (38.5 ± 15.1 years, 52.4% male, 39.2% prior sustained VA) according to four algorithms. Clinical performance was evaluated by sensitivity, specificity, ROC-analysis, and decision curve analysis for any sustained VA and for fast VA (>250 b.p.m.). During 6.4 [2.8–11.5] years follow-up, 282 (45.7%) patients experienced any sustained VA, and 63 (10.2%) fast VA. For any sustained VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (94.0–97.8% vs. 76.7–83.5%), but lower specificity (15.9–32.0% vs. 42.7%-60.1%). Similarly, for fast VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (95.2–97.1% vs. 76.7–78.4%) but lower specificity (42.7–43.1 vs. 76.7–78.4%). Decision curve analysis showed ITFC and mITFC to be superior for a 5-year sustained VA risk ICD indication threshold between 5–25% or 2–9% for fast VA. Conclusion: The ITFC and mITFC provide the highest protection rates, whereas AHA and HRS decrease unnecessary ICD placements. ITFC or mITFC should be used if we consider the 5-year threshold for ICD indication to lie within 5–25% for sustained VA or 2–9% for fast VA. These data will inform decision-making for ICD placement in ARVC. … (more)
- Is Part Of:
- Europace. Volume 24:Issue 2(2022)
- Journal:
- Europace
- Issue:
- Volume 24:Issue 2(2022)
- Issue Display:
- Volume 24, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 24
- Issue:
- 2
- Issue Sort Value:
- 2022-0024-0002-0000
- Page Start:
- 296
- Page End:
- 305
- Publication Date:
- 2021-09-02
- Subjects:
- Arrhythmogenic right ventricular cardiomyopathy -- Prognosis -- Risk stratification -- Implantable cardioverter-defibrillator -- Ventricular arrhythmias
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euab162 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20703.xml