TBS-BAO: fully automated beam angle optimization for IMRT guided by a total-beam-space reference plan. (28th January 2022)
- Record Type:
- Journal Article
- Title:
- TBS-BAO: fully automated beam angle optimization for IMRT guided by a total-beam-space reference plan. (28th January 2022)
- Main Title:
- TBS-BAO: fully automated beam angle optimization for IMRT guided by a total-beam-space reference plan
- Authors:
- Schipaanboord, B W K
Heijmen, B J M
Breedveld, S - Abstract:
- Abstract: Properly selected beam angles contribute to the quality of radiotherapy treatment plans. However, the beam angle optimization (BAO) problem is difficult to solve to optimality due to its non-convex discrete nature with many local minima. In this study, we propose TBS-BAO, a novel approach for solving the BAO problem, and test it for non-coplanar robotic CyberKnife radiotherapy for prostate cancer. First, an ideal Pareto-optimal reference dose distribution is automatically generated using a priori multi-criterial fluence map optimization (FMO) to generate a plan that includes all candidate beams (total-beam-space, TBS). Then, this ideal dose distribution is reproduced as closely as possible in a subsequent segmentation/beam angle optimization step (SEG/BAO), while limiting the number of allowed beams to a user-selectable preset value. SEG/BAO aims at a close reproduction of the ideal dose distribution. For each of 33 prostate SBRT patients, 18 treatment plans with different pre-set numbers of allowed beams were automatically generated with the proposed TBS-BAO. For each patient, the TBS-BAO plans were then compared to a plan that was automatically generated with an alternative BAO method (Erasmus-iCycle) and to a high-quality manually generated plan. TBS-BAO was able to automatically generate plans with clinically feasible numbers of beams (∼25), with a quality highly similar to corresponding 91-beam ideal reference plans. Compared to the alternative Erasmus-iCycleAbstract: Properly selected beam angles contribute to the quality of radiotherapy treatment plans. However, the beam angle optimization (BAO) problem is difficult to solve to optimality due to its non-convex discrete nature with many local minima. In this study, we propose TBS-BAO, a novel approach for solving the BAO problem, and test it for non-coplanar robotic CyberKnife radiotherapy for prostate cancer. First, an ideal Pareto-optimal reference dose distribution is automatically generated using a priori multi-criterial fluence map optimization (FMO) to generate a plan that includes all candidate beams (total-beam-space, TBS). Then, this ideal dose distribution is reproduced as closely as possible in a subsequent segmentation/beam angle optimization step (SEG/BAO), while limiting the number of allowed beams to a user-selectable preset value. SEG/BAO aims at a close reproduction of the ideal dose distribution. For each of 33 prostate SBRT patients, 18 treatment plans with different pre-set numbers of allowed beams were automatically generated with the proposed TBS-BAO. For each patient, the TBS-BAO plans were then compared to a plan that was automatically generated with an alternative BAO method (Erasmus-iCycle) and to a high-quality manually generated plan. TBS-BAO was able to automatically generate plans with clinically feasible numbers of beams (∼25), with a quality highly similar to corresponding 91-beam ideal reference plans. Compared to the alternative Erasmus-iCycle BAO approach, similar plan quality was obtained for 25-beam segmented plans, while computation times were reduced from 10.7 hours to 4.8/1.5 hours, depending on the applied pencil-beam resolution in TBS-BAO. 25-beam TBS-BAO plans had similar quality as manually generated plans with on average 48 beams, while delivery times reduced from 22.3 to 18.4/18.1 min. TBS reference plans could effectively steer the discrete non-convex BAO. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 67:Number 3(2022)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 67:Number 3(2022)
- Issue Display:
- Volume 67, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 67
- Issue:
- 3
- Issue Sort Value:
- 2022-0067-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01-28
- Subjects:
- beam angle optimization (BAO) -- multi-criterial plan optimization (MCO) -- treatment plan segmentation -- Pareto-optimal IMRT plan -- prostate cancer
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/ac4b37 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20692.xml