High-resolution impact assessment of climate change on building energy performance considering extreme weather events and microclimate – Investigating variations in indoor thermal comfort and degree-days. (March 2022)
- Record Type:
- Journal Article
- Title:
- High-resolution impact assessment of climate change on building energy performance considering extreme weather events and microclimate – Investigating variations in indoor thermal comfort and degree-days. (March 2022)
- Main Title:
- High-resolution impact assessment of climate change on building energy performance considering extreme weather events and microclimate – Investigating variations in indoor thermal comfort and degree-days
- Authors:
- Hosseini, Mohammad
Javanroodi, Kavan
Nik, Vahid M. - Abstract:
- Abstract : Exploiting a high-resolution building energy model of two residential blocks in Sweden. Considering 13 future weather scenarios besides typical and extreme conditions. Impacts of microclimate emerge significantly during nighttime and warm seasons. Climate change can considerably reduce indoor thermal comfort. Peak cooling loads increase by 210% and 290% at the middle and end of the century. Cooling systems are essential to maintain thermal comfort in the future. Abstract: Climate change and urbanization are two major challenges when planning for sustainable energy transition in cities. The common approach for energy demand estimation is using only typical meso-scale weather data in building energy models (BEMs), which underestimates the impacts of extreme climate and microclimate variations. To quantify the impacts of such underestimation on assessing the future energy performance of buildings, this study simulates a high spatiotemporal resolution BEM for two representative residential buildings located in a 600 × 600 m2 urban area in Southeast Sweden while accounting for both climate change and microclimate. Future climate data are synthesized using 13 future climate scenarios over 2010-2099, divided into three 30-year periods, and microclimate data are generated considering the urban morphology of the area. It is revealed that microclimate can cause 17% rise in cooling degree-day (CDD) and 7% reduction in heating degree-day (HDD) on average compared toAbstract : Exploiting a high-resolution building energy model of two residential blocks in Sweden. Considering 13 future weather scenarios besides typical and extreme conditions. Impacts of microclimate emerge significantly during nighttime and warm seasons. Climate change can considerably reduce indoor thermal comfort. Peak cooling loads increase by 210% and 290% at the middle and end of the century. Cooling systems are essential to maintain thermal comfort in the future. Abstract: Climate change and urbanization are two major challenges when planning for sustainable energy transition in cities. The common approach for energy demand estimation is using only typical meso-scale weather data in building energy models (BEMs), which underestimates the impacts of extreme climate and microclimate variations. To quantify the impacts of such underestimation on assessing the future energy performance of buildings, this study simulates a high spatiotemporal resolution BEM for two representative residential buildings located in a 600 × 600 m2 urban area in Southeast Sweden while accounting for both climate change and microclimate. Future climate data are synthesized using 13 future climate scenarios over 2010-2099, divided into three 30-year periods, and microclimate data are generated considering the urban morphology of the area. It is revealed that microclimate can cause 17% rise in cooling degree-day (CDD) and 7% reduction in heating degree-day (HDD) on average compared to mesoclimate. Considering typical weather conditions, CDD increases by 45% and HDD decreases by 8% from one 30-year period to another. Differences can become much larger during extreme weather conditions. For example, CDD can increase by 500% in an extreme warm July compared to a typical one. Results also indicate that annual cooling demand becomes four and five times bigger than 2010-2039 in 2040-2069 and 2070-2099, respectively. The daily peak cooling load can increase up to 25% in an extreme warm day when accounting for microclimate. In the absence of cooling systems during extreme warm days, the indoor temperature stays above 26°C continuously over a week and reaches above 29.2°C. Moreover, the annual overheating hours can increase up to 140% in the future. These all indicate that not accounting for influencing climate variations can result in maladaptation or insufficient adaptation of urban areas to climate change. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Sustainable cities and society. Volume 78(2022)
- Journal:
- Sustainable cities and society
- Issue:
- Volume 78(2022)
- Issue Display:
- Volume 78, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 78
- Issue:
- 2022
- Issue Sort Value:
- 2022-0078-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- Climate change adaptation -- Extreme climate events -- Urban microclimate -- Urban heat island -- Indoor thermal comfort -- Building energy performance
Sustainable urban development -- Periodicals
Sustainable buildings -- Periodicals
Urban ecology (Sociology) -- Periodicals
307.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22106707/ ↗
http://www.sciencedirect.com/ ↗
http://www.journals.elsevier.com/sustainable-cities-and-society ↗ - DOI:
- 10.1016/j.scs.2021.103634 ↗
- Languages:
- English
- ISSNs:
- 2210-6707
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20686.xml