Respiratory monitoring during neonatal resuscitation using a supraglottic airway device vs. a face mask. (February 2022)
- Record Type:
- Journal Article
- Title:
- Respiratory monitoring during neonatal resuscitation using a supraglottic airway device vs. a face mask. (February 2022)
- Main Title:
- Respiratory monitoring during neonatal resuscitation using a supraglottic airway device vs. a face mask
- Authors:
- Pejovic, Nicolas J.
Cavallin, Francesco
Mpamize, Allan
Lubulwa, Clare
Höök, Susanna Myrnerts
Byamugisha, Josaphat
Nankunda, Jolly
Tylleskär, Thorkild
Trevisanuto, Daniele - Abstract:
- Abstract: Objective: To evaluate the respiratory function of asphyxiated infants resuscitated with i-gel supraglottic airway (SGA) vs. face mask (FM) in a low-resource setting. Methods: In this sub-study from the NeoSupra trial, respiratory function during the first 60 inflations was evaluated in 46 neonates (23 with SGA and 23 with FM) at the Mulago National Referral Hospital, Uganda. The primary outcome was the mask leak (%). The secondary outcomes included inspired (VTi) and expired (VTe) tidal volumes, and heart rate response to ventilation. Results: Median mask leak was 40% (IQR 22–52) with SGA and 39% (IQR 26–62) with FM (p = 0.38). Median VTe was 7.8 ml/kg (IQR 5.6–10.2) with SGA and 7.3 ml/kg (IQR 4.8–11.9) with FM (p = 0.84), while median VTi was 15.4 ml/kg (IQR 11–4-17.6) with SGA and 15.9 ml/kg (IQR 9.0–22.6) with FM (p = 0.68). A shorter time was needed to achieve heart rate > 100 bpm in SGA (median 13 s IQR 9–15) with respect to FM arm (median 61, IQR 33–140) (p = 0.0002). Conclusion: Respiratory function was not statistically different between neonates resuscitated with SGA vs. FM. SGA was associated with faster heart rate recovery compared to FM in the subgroup of neonates with bradycardia. Further research is needed to investigate possible advantages of SGA on respiratory function at birth.
- Is Part Of:
- Resuscitation. Volume 171(2022)
- Journal:
- Resuscitation
- Issue:
- Volume 171(2022)
- Issue Display:
- Volume 171, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 171
- Issue:
- 2022
- Issue Sort Value:
- 2022-0171-2022-0000
- Page Start:
- 107
- Page End:
- 113
- Publication Date:
- 2022-02
- Subjects:
- Birth asphyxia -- Global health -- Intrapartum-related complications -- Laryngeal mask -- Newborn infant -- Resuscitation
ECG Electrocardiogram -- FM Face Mask -- FMV Face Mask Ventilation -- HBB Helping Babies Breathe -- HR Heart Rate -- IQR Inter Quartile Range -- SGA Supraglottic Airway -- MHREC Mulago Hospital Research and Ethics Committee -- PIP Peak Inspiratory Pressure -- PPV Positive Pressure Ventilation -- RCN Research Council of Norway -- RFM Respiratory Function Monitoring -- SD Standard Deviation -- VTe Expired Tidal Volume -- VTi Inspired Tidal Volume
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2021.10.025 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20668.xml