Re-worsening left ventricular ejection fraction after response to cardiac resynchronization therapy. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Re-worsening left ventricular ejection fraction after response to cardiac resynchronization therapy. Issue 3 (March 2022)
- Main Title:
- Re-worsening left ventricular ejection fraction after response to cardiac resynchronization therapy
- Authors:
- Oki, Takumi
Ishii, Shunsuke
Takigami, Yu
Eda, Yuko
Maemura, Kenji
Yazaki, Mayu
Fujita, Teppei
Ikeda, Yuki
Nabeta, Takeru
Maekawa, Emi
Koitabashi, Toshimi
Ako, Junya - Abstract:
- Highlight: One-third of responders to cardiac resynchronization therapy (CRT) experienced re-worsening left ventricular (LV) function subsequently. Re-worsening LV function after CRT response was associated with poor outcomes. Timing of CRT implantation and QRS morphology affected LV function after CRT response. Lower increase in LV ejection fraction after CRT predicted for re-worsening LV function. Abstract: Background: Although cardiac resynchronization therapy (CRT) provided functional and clinical improvement in patients with heart failure (HF) and electrical intraventricular conduction disturbances, some patients had re-worsening left ventricular (LV) function after a favorable CRT response. We analyzed the clinical variables and cardiac outcomes associated with this re-worsening LV function after CRT. Methods: In this study, 71 patients with CRT response who received CRT between 2006 and 2017 were included. CRT response was defined as a "≥ 10% improvement in LV ejection fraction (LVEF) on follow-up." Patients were classified into two groups: (i) persistent: ( n = 48, 68%), defined as those with a CRT response and (ii) re-worsening: ( n = 23, 32%), consisting of those who fell out of the definition of a CRT response after an initial CRT response. Results: Half of the patients in the re-worsening group failed to maintain a CRT response from two years upwards. A longer duration from HF diagnosis to CRT implantation, nonspecific intraventricular conduction delay (NIVCD)Highlight: One-third of responders to cardiac resynchronization therapy (CRT) experienced re-worsening left ventricular (LV) function subsequently. Re-worsening LV function after CRT response was associated with poor outcomes. Timing of CRT implantation and QRS morphology affected LV function after CRT response. Lower increase in LV ejection fraction after CRT predicted for re-worsening LV function. Abstract: Background: Although cardiac resynchronization therapy (CRT) provided functional and clinical improvement in patients with heart failure (HF) and electrical intraventricular conduction disturbances, some patients had re-worsening left ventricular (LV) function after a favorable CRT response. We analyzed the clinical variables and cardiac outcomes associated with this re-worsening LV function after CRT. Methods: In this study, 71 patients with CRT response who received CRT between 2006 and 2017 were included. CRT response was defined as a "≥ 10% improvement in LV ejection fraction (LVEF) on follow-up." Patients were classified into two groups: (i) persistent: ( n = 48, 68%), defined as those with a CRT response and (ii) re-worsening: ( n = 23, 32%), consisting of those who fell out of the definition of a CRT response after an initial CRT response. Results: Half of the patients in the re-worsening group failed to maintain a CRT response from two years upwards. A longer duration from HF diagnosis to CRT implantation, nonspecific intraventricular conduction delay (NIVCD) on electrocardiogram at CRT implantation, and a lower increased LVEF at initial CRT response were independent predictors for the re-worsening group. Patients in the re-worsening group had a higher incidence rate for HF hospitalization and cardiac deaths, compared with those in the persistent group. Conclusion: One-third of CRT responders experienced re-worsening LVEF, which was associated with poor outcomes. CRT responders with NIVCD, longer HF duration, and a lower increased LVEF at initial CRT response should be monitored with caution. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Journal of cardiology. Volume 79:Issue 3(2022)
- Journal:
- Journal of cardiology
- Issue:
- Volume 79:Issue 3(2022)
- Issue Display:
- Volume 79, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 79
- Issue:
- 3
- Issue Sort Value:
- 2022-0079-0003-0000
- Page Start:
- 358
- Page End:
- 364
- Publication Date:
- 2022-03
- Subjects:
- Cardiac resynchronization therapy -- Re-worsening -- Nonspecific intraventricular conduction disturbance -- Heart failure duration
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/09145087 ↗
http://www.sciencedirect.com/science/journal/09145087 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jjcc.2021.10.010 ↗
- Languages:
- English
- ISSNs:
- 0914-5087
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.864200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20670.xml