Monte Carlo simulations and phantom validation of low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope. (February 2022)
- Record Type:
- Journal Article
- Title:
- Monte Carlo simulations and phantom validation of low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope. (February 2022)
- Main Title:
- Monte Carlo simulations and phantom validation of low-dose radiotherapy to the lungs using an interventional radiology C-arm fluoroscope
- Authors:
- Roa, D.
Leon, S.
Paucar, O.
Gonzales, A.
Schwarz, B.
Olguin, E.
Moskvin, V.
Alva-Sanchez, M.
Glassell, M.
Correa, N.
Moyses, H.
Shankar, A.
Hamrick, B.
Sarria, G.R.
Li, B.
Tajima, T.
Necas, A.
Guzman, C.
Challco, R.
Montoya, M.
Meza, Z.
Zapata, M.
Gonzales, A.
Marquez, F.
Neira, R.
Vilca, W.
Mendez, J.
Hernandez, J. - Abstract:
- Highlights: kV x-rays can deliver an effective low-dose radiotherapy to a COVID-19 patient. Suitable field arrangements result in a homogeneous dose distribution to the lungs. kV x-rays low-dose radiotherapy could be a treatment option until vaccines reach those regions. Low-income countries could benefit from this immediate treatment option. Abstract: Purpose: To use MC simulations and phantom measurements to investigate the dosimetry of a kilovoltage x-ray beam from an IR fluoroscope to deliver low-dose (0.3–1.0 Gy) radiotherapy to the lungs. Materials and Methods: PENELOPE was used to model a 125 kV, 5.94 mm Al HVL x-ray beam produced by a fluoroscope. The model was validated through depth-dose, in-plane/cross-plane profiles and absorbed dose at 2.5-, 5.1-, 10.2- and 15.2-cm depths against the measured beam in an acrylic phantom. CT images of an anthropomorphic phantom thorax/lungs were used to simulate 0.5 Gy dose distributions for PA, AP/PA, 3-field and 4-field treatments. DVHs were generated to assess the dose to the lungs and nearby organs. Gafchromic film was used to measure doses in the phantom exposed to PA and 4-field treatments, and compared to the MC simulations. Results: Depth-dose and profile results were within 3.2% and 7.8% of the MC data uncertainty, respectively, while dose gamma analysis ranged from 0.7 to 1.0. Mean dose to the lungs were 1.1-, 0.8-, 0.9-, and 0.8- Gy for the PA, AP/PA, 3-field, and 4-field after isodose normalization to cover ∼ 95% ofHighlights: kV x-rays can deliver an effective low-dose radiotherapy to a COVID-19 patient. Suitable field arrangements result in a homogeneous dose distribution to the lungs. kV x-rays low-dose radiotherapy could be a treatment option until vaccines reach those regions. Low-income countries could benefit from this immediate treatment option. Abstract: Purpose: To use MC simulations and phantom measurements to investigate the dosimetry of a kilovoltage x-ray beam from an IR fluoroscope to deliver low-dose (0.3–1.0 Gy) radiotherapy to the lungs. Materials and Methods: PENELOPE was used to model a 125 kV, 5.94 mm Al HVL x-ray beam produced by a fluoroscope. The model was validated through depth-dose, in-plane/cross-plane profiles and absorbed dose at 2.5-, 5.1-, 10.2- and 15.2-cm depths against the measured beam in an acrylic phantom. CT images of an anthropomorphic phantom thorax/lungs were used to simulate 0.5 Gy dose distributions for PA, AP/PA, 3-field and 4-field treatments. DVHs were generated to assess the dose to the lungs and nearby organs. Gafchromic film was used to measure doses in the phantom exposed to PA and 4-field treatments, and compared to the MC simulations. Results: Depth-dose and profile results were within 3.2% and 7.8% of the MC data uncertainty, respectively, while dose gamma analysis ranged from 0.7 to 1.0. Mean dose to the lungs were 1.1-, 0.8-, 0.9-, and 0.8- Gy for the PA, AP/PA, 3-field, and 4-field after isodose normalization to cover ∼ 95% of each lung volume. Skin dose toxicity was highest for the PA and lowest for the 4-field, and both arrangements successfully delivered the treatment on the phantom. However, the dose distribution for the PA was highly non-uniform and produced skin doses up to 4 Gy. The dose distribution for the 4-field produced a uniform 0.6 Gy dose throughout the lungs, with a maximum dose of 0.73 Gy. The average percent difference between experimental and Monte Carlo values were −0.1% (range −3% to +4%) for the PA treatment and 0.3% (range −10.3% to +15.2%) for the 4-field treatment. Conclusion: A 125 kV x-ray beam from an IR fluoroscope delivered through two or more fields can deliver an effective low-dose radiotherapy treatment to the lungs. The 4-field arrangement not only provides an effective treatment, but also significant dose sparing to healthy organs, including skin, compared to the PA treatment. Use of fluoroscopy appears to be a viable alternative to megavoltage radiation therapy equipment for delivering low-dose radiotherapy to the lungs. … (more)
- Is Part Of:
- Physica medica. Volume 94(2022)
- Journal:
- Physica medica
- Issue:
- Volume 94(2022)
- Issue Display:
- Volume 94, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 94
- Issue:
- 2022
- Issue Sort Value:
- 2022-0094-2022-0000
- Page Start:
- 24
- Page End:
- 34
- Publication Date:
- 2022-02
- Subjects:
- Monte Carlo -- Radiotherapy -- Pneumonia -- Kilovoltage x-rays -- Low dose -- Fluoroscopes
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2021.12.014 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20670.xml