Clinical evaluation of a novel head protection system for interventional radiologists. Issue 147 (February 2022)
- Record Type:
- Journal Article
- Title:
- Clinical evaluation of a novel head protection system for interventional radiologists. Issue 147 (February 2022)
- Main Title:
- Clinical evaluation of a novel head protection system for interventional radiologists
- Authors:
- Bärenfänger, Felix
Walbersloh, Jörg
El Mouden, Rachid
Goerg, Fabian
Block, Andreas
Rohde, Stefan - Abstract:
- Abstract: Purpose: A novel two-part protective system consisting of a modified thyroid collar and a head protection is intended to reduce the radiation dose to the examiners head during fluoroscopy-guided interventions. In this pilot study, we tested this protection system under real-life conditions in general radiological and neuroradiological interventions. Methods: Two sets of the protection system (set A and B) were equipped with 12 thermoluminiscence detectors (TLD). For simultaneous measurement of radiation exposure and dose-reduction, each six TLDs were fixed to the inner side and on the corresponding outer side of the protection system. Set A was used exclusively for general radiological interventions and set B exclusively for neuroradiological interventions. To compare the staff exposure in general radiology and neuroradiology, dose values were normalized to a DAP of 10 000 µGy∙m 2 . Results: The sets were tested during 20 general radiological interventions and 32 neuroradiological interventions. In neuroradiology, the mean normalized radiation exposure was 13.44 ± 1.36 µSv/10 000 µGy∙m 2 at the head protection and 22.27 ± 2.09 µSv/10 000 µGy∙m 2 at the thyroid collar. In general radiology, the corresponding results were 29.91 ± 4.19 µSv/10 000 µGy∙m 2 (head protection) and 68.07 ± 17.25 µSv/10 000 µGy∙m 2 (thyroid collar). Thus, mean dose exposure was 2.5 times higher in general radiological interventions (p = 0.016). The use of the protection system resulted in aAbstract: Purpose: A novel two-part protective system consisting of a modified thyroid collar and a head protection is intended to reduce the radiation dose to the examiners head during fluoroscopy-guided interventions. In this pilot study, we tested this protection system under real-life conditions in general radiological and neuroradiological interventions. Methods: Two sets of the protection system (set A and B) were equipped with 12 thermoluminiscence detectors (TLD). For simultaneous measurement of radiation exposure and dose-reduction, each six TLDs were fixed to the inner side and on the corresponding outer side of the protection system. Set A was used exclusively for general radiological interventions and set B exclusively for neuroradiological interventions. To compare the staff exposure in general radiology and neuroradiology, dose values were normalized to a DAP of 10 000 µGy∙m 2 . Results: The sets were tested during 20 general radiological interventions and 32 neuroradiological interventions. In neuroradiology, the mean normalized radiation exposure was 13.44 ± 1.36 µSv/10 000 µGy∙m 2 at the head protection and 22.27 ± 2.09 µSv/10 000 µGy∙m 2 at the thyroid collar. In general radiology, the corresponding results were 29.91 ± 4.19 µSv/10 000 µGy∙m 2 (head protection) and 68.07 ± 17.25 µSv/10 000 µGy∙m 2 (thyroid collar). Thus, mean dose exposure was 2.5 times higher in general radiological interventions (p = 0.016). The use of the protection system resulted in a mean dose reduction of 81.2 ± 11.1 % (general radiology) and 92.1 ± 4.2 % (neuroradiology; p = 0.016). Conclusion: Fluoroscopy-guided interventions lead to significant radiation exposure of the head area for the examiner. The novel protection system tested led to a significant dose reduction of 80–90%, depending on the type of intervention. … (more)
- Is Part Of:
- European journal of radiology. Issue 147(2022)
- Journal:
- European journal of radiology
- Issue:
- Issue 147(2022)
- Issue Display:
- Volume 147, Issue 147 (2022)
- Year:
- 2022
- Volume:
- 147
- Issue:
- 147
- Issue Sort Value:
- 2022-0147-0147-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02
- Subjects:
- Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2021.110114 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20653.xml