Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments. (22nd August 2016)
- Record Type:
- Journal Article
- Title:
- Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments. (22nd August 2016)
- Main Title:
- Dual crystal x-ray spectrometer at 1.8 keV for high repetition-rate single-photon counting spectroscopy experiments
- Authors:
- Gamboa, E.J.
Bachmann, B.
Kraus, D.
MacDonald, M.J.
Bucher, M.
Carron, S.
Coffee, R.N.
Drake, R.P.
Emig, J.
Ferguson, K.R.
Fletcher, L.B.
Glenzer, S.H.
Gorkhover, T.
Hau-Riege, S.P.
Krzywinski, J.
Levitan, A.L.
Meiwes-Broer, K.-H.
Osipov, T.
Pardini, T.
Peltz, C.
Skruszewicz, S.
Bostedt, C.
Fennel, T.
Döppner, T. - Abstract:
- Abstract: With the recent development of high-repetition rate x-ray free electron lasers (FEL), it is now possible to perform x-ray scattering and emission spectroscopy measurements from thin foils or gasses heated to high-energy density conditions by integrating over many experimental shots. Since the expected signal may be weaker than the typical CCD readout noise over the region-of-interest, it is critical to the success of this approach to use a detector with high-energy resolution so that single x-ray photons may be isolated. Here we describe a dual channel x-ray spectrometer developed for the Atomic and Molecular Optics endstation at the Linac Coherent Light Source (LCLS) for x-ray spectroscopy near the K-edge of aluminum. The spectrometer is based on a pair of curved PET (002) crystals coupled to a single pnCCD detector which simultaneously measures x-ray scattering and emission in the forward and backward directions. The signals from single x-ray photons are accumulated permitting continuous single-shot acquisition at 120 Hz.
- Is Part Of:
- Journal of instrumentation. Volume 11:Number 8(2016:Aug.)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 11:Number 8(2016:Aug.)
- Issue Display:
- Volume 11, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 8
- Issue Sort Value:
- 2016-0011-0008-0000
- Page Start:
- P08015
- Page End:
- P08015
- Publication Date:
- 2016-08-22
- Subjects:
- Nuclear instruments and methods for hot plasma diagnostics -- Plasma diagnostics - interferometry, spectroscopy and imaging -- Plasma generation (laser-produced, RF, x ray-produced)
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/11/08/P08015 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20665.xml