Impact of inter‐vendor variability on evaluation of left ventricular mechanical dispersion. Issue 1 (6th December 2021)
- Record Type:
- Journal Article
- Title:
- Impact of inter‐vendor variability on evaluation of left ventricular mechanical dispersion. Issue 1 (6th December 2021)
- Main Title:
- Impact of inter‐vendor variability on evaluation of left ventricular mechanical dispersion
- Authors:
- Appadurai, Vinesh
Scalia, Gregory M.
Lau, Katherine
Chamberlain, Robert
Edwards, Natalie
Bushell, Hannah
Scalia, William
Tomlinson, Stephen
Hamilton‐Craig, Christian
Chan, Jonathan - Abstract:
- Abstract: Purpose: Left ventricular mechanical dispersion (LVMD) is a novel speckle tracking parameter for prognostic assessment of arrhythmic risk prediction. There is growing evidence to support its use in a variety of cardiomyopathic processes. There is paucity of data addressing any presence of inter‐vendor discrepancies for LVMD. The aim of this study was to assess inter‐vendor variability of LVMD in vendor specific software (VSS) and vendor independent software (VIS) in subjects with preserved and reduced left ventricular function. Methods: Fifty‐nine subjects (14 normal subjects and 45 subjects with cardiac disease) were recruited and 2D speckle tracking echocardiographic images were acquired on two different ultrasound machines (GE and Philips). LVMD was measured by two different VSS (EchoPac GE and QLAB Philips) and one VIS (TomTec Arena). Results: There was significant bias and wide limits of agreement (LOA) in the overall cohort observed between two different VSS (17.6 ms; LOA: ‐29.6 to 64.8; r : .47). There was acceptable bias and narrower LOA with good agreement for LVMD between images obtained on different vendors when performed on VIS (‐3.1 ms; LOA: ‐27.6 to 21.4; r : .75). QLAB LVMD was consistently higher than GE LVMD and TomTec LVMD in both preserved and reduced left ventricular function. LVMD measurements have high intra‐vendor reproducibility with excellent inter and intra‐observer agreement. Conclusions: There was acceptable bias and narrower LOA forAbstract: Purpose: Left ventricular mechanical dispersion (LVMD) is a novel speckle tracking parameter for prognostic assessment of arrhythmic risk prediction. There is growing evidence to support its use in a variety of cardiomyopathic processes. There is paucity of data addressing any presence of inter‐vendor discrepancies for LVMD. The aim of this study was to assess inter‐vendor variability of LVMD in vendor specific software (VSS) and vendor independent software (VIS) in subjects with preserved and reduced left ventricular function. Methods: Fifty‐nine subjects (14 normal subjects and 45 subjects with cardiac disease) were recruited and 2D speckle tracking echocardiographic images were acquired on two different ultrasound machines (GE and Philips). LVMD was measured by two different VSS (EchoPac GE and QLAB Philips) and one VIS (TomTec Arena). Results: There was significant bias and wide limits of agreement (LOA) in the overall cohort observed between two different VSS (17.6 ms; LOA: ‐29.6 to 64.8; r : .47). There was acceptable bias and narrower LOA with good agreement for LVMD between images obtained on different vendors when performed on VIS (‐3.1 ms; LOA: ‐27.6 to 21.4; r : .75). QLAB LVMD was consistently higher than GE LVMD and TomTec LVMD in both preserved and reduced left ventricular function. LVMD measurements have high intra‐vendor reproducibility with excellent inter and intra‐observer agreement. Conclusions: There was acceptable bias and narrower LOA for LVMD assessment on a VIS. Inter‐vendor variability exists for LVMD assessment between VSS. Serial measurements of LVMD should be performed using a single vendor for consistent and reliable results. … (more)
- Is Part Of:
- Echocardiography. Volume 39:Issue 1(2022)
- Journal:
- Echocardiography
- Issue:
- Volume 39:Issue 1(2022)
- Issue Display:
- Volume 39, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2022-0039-0001-0000
- Page Start:
- 54
- Page End:
- 64
- Publication Date:
- 2021-12-06
- Subjects:
- Inter‐vendor variability -- left ventricular mechanical dispersion -- speckle tracking echocardiography
Echocardiography -- Periodicals
Echocardiography -- Periodicals
616.1207543 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8175 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/echo.15270 ↗
- Languages:
- English
- ISSNs:
- 0742-2822
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3647.572500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20665.xml