Onsite measurement and performance analysis of capillary heat pump system used in subway tunnels. (5th March 2022)
- Record Type:
- Journal Article
- Title:
- Onsite measurement and performance analysis of capillary heat pump system used in subway tunnels. (5th March 2022)
- Main Title:
- Onsite measurement and performance analysis of capillary heat pump system used in subway tunnels
- Authors:
- Tong, Zhen
Guan, Yiming
Cao, Tingtao
Ji, Yongming
Hu, Songtao
Liu, Guodan
Liu, Nan
Fan, Yujing - Abstract:
- Highlights: First real application of capillary ground source heat pump in subway tunnel was reported in this paper. Energy efficiency of the system was evaluated by onsite measurement. The heat transfer ability of the capillary heat exchanger in summer and winter was tested. Energy efficiency of the system could be improved under intermittent operation in summer. Abstract: This study proposed a ground source heat pump system using capillary networks as the front-end heat exchanger, to alleviate thermal pollution and utilize waste heat generated in subway tunnels and the surrounding rock. We conducted onsite measurement of the capillary ground source heat pump system based on a real engineering project involving a subway tunnel. Subsequently, the heat transfer performance of the capillary heat exchanger and energy efficiency of the system were analyzed. The heat transfer capacity of the capillary heat exchanger was approximately 45–80 and 100–110 W/m 2 in a test with a duration of 7 h in winter and a test with a duration of 14 h in summer, respectively. The average coefficient of performance of the heat pump unit and coefficient of performance of the system were 3.72 and 3.18, respectively, in winters, and 3.19 and 2.64, respectively, in summers. Under a 4-day test with an intermittent operation of 8 h per day in summer, the performance of the system was improved and remained stable for four days during the test. The average coefficient of performance of the heat pump unitHighlights: First real application of capillary ground source heat pump in subway tunnel was reported in this paper. Energy efficiency of the system was evaluated by onsite measurement. The heat transfer ability of the capillary heat exchanger in summer and winter was tested. Energy efficiency of the system could be improved under intermittent operation in summer. Abstract: This study proposed a ground source heat pump system using capillary networks as the front-end heat exchanger, to alleviate thermal pollution and utilize waste heat generated in subway tunnels and the surrounding rock. We conducted onsite measurement of the capillary ground source heat pump system based on a real engineering project involving a subway tunnel. Subsequently, the heat transfer performance of the capillary heat exchanger and energy efficiency of the system were analyzed. The heat transfer capacity of the capillary heat exchanger was approximately 45–80 and 100–110 W/m 2 in a test with a duration of 7 h in winter and a test with a duration of 14 h in summer, respectively. The average coefficient of performance of the heat pump unit and coefficient of performance of the system were 3.72 and 3.18, respectively, in winters, and 3.19 and 2.64, respectively, in summers. Under a 4-day test with an intermittent operation of 8 h per day in summer, the performance of the system was improved and remained stable for four days during the test. The average coefficient of performance of the heat pump unit and of the system for intermittent operation were 3.67 and 2.96, respectively, which were larger than those for 14 h continuous operation in summer. In practical applications, intermittent operation or additional auxiliary cooling sources are recommended in summer conditions. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 204(2022)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 204(2022)
- Issue Display:
- Volume 204, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 204
- Issue:
- 2022
- Issue Sort Value:
- 2022-0204-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03-05
- Subjects:
- Subway tunnel -- Ground source heat pump -- Capillary heat exchanger -- Onsite measurement -- Performance analysis
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2021.118008 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20649.xml