Measuring breathability and bacterial filtration efficiency of face masks in the pandemic context: A round robin study with proficiency testing among non-accredited laboratories. (15th February 2022)
- Record Type:
- Journal Article
- Title:
- Measuring breathability and bacterial filtration efficiency of face masks in the pandemic context: A round robin study with proficiency testing among non-accredited laboratories. (15th February 2022)
- Main Title:
- Measuring breathability and bacterial filtration efficiency of face masks in the pandemic context: A round robin study with proficiency testing among non-accredited laboratories
- Authors:
- Tessarolo, Francesco
Nollo, Giandomenico
Benedetti, Luca
Helfer, Fabrizia
Rovati, Luigi
Ferrari, Alberto
Marchetti, Giulio
Reverberi, Federico
Baglio, Salvo
Tuccitto, Nunzio
Stefani, Stefania
Stracquadanio, Stefano
Caraci, Filippo
Terrasi, Antonio
Tricomi, Alessia
Musumeci, Mario
Miraglia, Andrea
Cuttone, Giacomo
Cosentino, Sofia
Agostino Vitali, Luca
Petrelli, Dezemona
Ilaria Ciancia, Sonia
Mingoia, Marina
Castellini, Paolo
Simoni, Serena
Montalto, Luigi
Baleani, Alessia
Chiariotti, Paolo
Paone, Nicola - Abstract:
- Highlights: Intra-lot variability impacts uncertainty of face masks performance measurement. BFE measurements above 98% have good repeatability and reproducibility. High uncertainty can be associated to BFE measurements of community masks. Non-accredited laboratories performed at a satisfactory level during pandemic emergency. Face-mask conformity standards should consider uncertainty of BFE and DP measurements. Abstract: Six Italian non-accredited laboratories participated to an interlaboratory study aimed at measuring Differential Pressure (DP) and Bacterial Filtration Efficiency (BFE) of three face-mask models using methods in-line with EN 14683 standard. Methodological non-conformities were annotated. Repeatability and reproducibility on quintuplicate samples were calculated according to ISO 5725-2. Sample stability was also assessed. Laboratories were ranked according to the total standard deviation over all samples and proficiency was evaluated using z-score according to ISO 13528. Although some non-conformities were present, performances for the DP measurements were always acceptable. One laboratory had to revise the bacterial suspension preparation for the BFE test. Overall, non-accredited laboratories working during pandemic emergency performed satisfactorily. Sample-to-sample variability impacted measurement repeatability. BFE values above 98% showed good repeatability (≤1.0%) and reproducibility (≤6.1%), but high BFE uncertainty was associated to community masks.Highlights: Intra-lot variability impacts uncertainty of face masks performance measurement. BFE measurements above 98% have good repeatability and reproducibility. High uncertainty can be associated to BFE measurements of community masks. Non-accredited laboratories performed at a satisfactory level during pandemic emergency. Face-mask conformity standards should consider uncertainty of BFE and DP measurements. Abstract: Six Italian non-accredited laboratories participated to an interlaboratory study aimed at measuring Differential Pressure (DP) and Bacterial Filtration Efficiency (BFE) of three face-mask models using methods in-line with EN 14683 standard. Methodological non-conformities were annotated. Repeatability and reproducibility on quintuplicate samples were calculated according to ISO 5725-2. Sample stability was also assessed. Laboratories were ranked according to the total standard deviation over all samples and proficiency was evaluated using z-score according to ISO 13528. Although some non-conformities were present, performances for the DP measurements were always acceptable. One laboratory had to revise the bacterial suspension preparation for the BFE test. Overall, non-accredited laboratories working during pandemic emergency performed satisfactorily. Sample-to-sample variability impacted measurement repeatability. BFE values above 98% showed good repeatability (≤1.0%) and reproducibility (≤6.1%), but high BFE uncertainty was associated to community masks. Our findings suggest that relevant face-mask conformity standards should consider uncertainty of BFE and DP measurements. … (more)
- Is Part Of:
- Measurement. Volume 189(2022)
- Journal:
- Measurement
- Issue:
- Volume 189(2022)
- Issue Display:
- Volume 189, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 189
- Issue:
- 2022
- Issue Sort Value:
- 2022-0189-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-02-15
- Subjects:
- Face mask -- Uncertainty -- Differential pressure -- Bacterial filtration efficiency -- Round robin -- COVID-19 -- SARS-CoV-2
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2021.110481 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20636.xml