A bifunctional immunosensor based on osmium nano-hydrangeas as a catalytic chromogenic and tinctorial signal output for folic acid detection. Issue 1 (25th November 2021)
- Record Type:
- Journal Article
- Title:
- A bifunctional immunosensor based on osmium nano-hydrangeas as a catalytic chromogenic and tinctorial signal output for folic acid detection. Issue 1 (25th November 2021)
- Main Title:
- A bifunctional immunosensor based on osmium nano-hydrangeas as a catalytic chromogenic and tinctorial signal output for folic acid detection
- Authors:
- Pan, Junkang
He, Qiyi
Lao, Zhiting
Zou, Yikui
Su, Jingyi
Li, Qinglan
Chen, Zekai
Cui, Xiping
Cai, Yanfei
Zhao, Suqing - Abstract:
- Abstract : Schematic of the bifunctional immunosensor based on osmium nano-hydrangeas as a catalytic chromogenic and tinctorial signal output for folic acid detection. Abstract : As a neglected member of the platinum group elements, osmium, the metal with the highest density in the earth, is very suitable for the preparation of a peroxidase with high catalytic activity and stability, and can also be associated with the development of a sensor. In this study, we accessed Os nano-hydrangeas (OsNHs) with one-pot synthesis and utilized them in a bifunctional immunosensor that can present both catalytic chromogenic and tinctorial signal for nanozyme-linked immunosorbent assay (NLISA) and lateral flow immunoassay (LFIA) for use in folic acid (FA) detection. In the OsNHs-NLISA, the linear range is from 9.42 to 167.53 ng mL −1 . The limit of detection (LOD) is 4.03 ng mL −1 and the IC50 value is 39.73 ng mL −1 . In OsNHs-LFIA, the visual cut-off value and limit of detection (v-LOD) are 100 ng mL −1 and 0.01 ng mL −1, respectively. Additionally, the outcome from the specificity and spiked sample analysis offered recovery from the spiked milk powder sample ranging from 93.9 to 103.6% with a coefficient of variation under 4.9%, compared with UPLC-MS/MS for a correlation of R 2 = 0.999 and admirable validation. The promising application of the OsNHs can also be used in other bioprobes, and this bifunctional immunosensor analysis mode is suitable for diversified analytes.
- Is Part Of:
- Analyst. Volume 147:Issue 1(2022)
- Journal:
- Analyst
- Issue:
- Volume 147:Issue 1(2022)
- Issue Display:
- Volume 147, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 147
- Issue:
- 1
- Issue Sort Value:
- 2022-0147-0001-0000
- Page Start:
- 55
- Page End:
- 65
- Publication Date:
- 2021-11-25
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d1an01432c ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20592.xml