Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck. (June 2022)
- Record Type:
- Journal Article
- Title:
- Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck. (June 2022)
- Main Title:
- Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck
- Authors:
- Özdemir-van Brunschot, Denise Michelle Daniëlle
Torsello, Giovanni Battista
Bernardini, Giulia
Litterscheid, Sarah
Torsello, Giovanni Federico
Beropoulis, Efthymios - Abstract:
- Purpose: We hypothesized that extending the proximal landing zone with the chimney technique could be beneficial in patients with a hyperangulated proximal aortic neck, defined as more > 60 degrees. Material and Methods: We retrospectively analyzed the outcome of prospectively collected data of patients treated by endovascular aneurysm repair (EVAR) for infrarenal aortic aneurysm with a hyperangulated proximal aortic neck. In all, 104 out of 130 patients were treated without (Group A) and 24 with the chimney endovascular aortic repair (ChEVAR, Group B). Primary outcome was technical and clinical success according to the reporting standards of the Society of Vascular Surgery. Results: The use of the chimney technique was associated with a significantly longer operation duration (167 vs. 93 min, p < .001), longer fluoroscopy time (44 vs.30 min, p = < .001), and larger amount of contrast medium used (149 vs. 127 ml, p = .03) but did not significantly improve technical (79.2% vs. 87.7%) and clinical success (54.2% vs. 68.9%). Aneurysm-related mortality was higher in group B (8.3% vs. = 0%, p < .001). Type IA endoleak was high in both groups at completion angiography (11.3% in Group A vs. 12.5% in Group B) and at follow-up (10.4% in Group A vs. 4.5% in Group B) without significant difference between the groups. Conclusions: Our data did not show a benefit of the primary use of the chimney technique in patients with a hyperangulated and short neck, although more studies arePurpose: We hypothesized that extending the proximal landing zone with the chimney technique could be beneficial in patients with a hyperangulated proximal aortic neck, defined as more > 60 degrees. Material and Methods: We retrospectively analyzed the outcome of prospectively collected data of patients treated by endovascular aneurysm repair (EVAR) for infrarenal aortic aneurysm with a hyperangulated proximal aortic neck. In all, 104 out of 130 patients were treated without (Group A) and 24 with the chimney endovascular aortic repair (ChEVAR, Group B). Primary outcome was technical and clinical success according to the reporting standards of the Society of Vascular Surgery. Results: The use of the chimney technique was associated with a significantly longer operation duration (167 vs. 93 min, p < .001), longer fluoroscopy time (44 vs.30 min, p = < .001), and larger amount of contrast medium used (149 vs. 127 ml, p = .03) but did not significantly improve technical (79.2% vs. 87.7%) and clinical success (54.2% vs. 68.9%). Aneurysm-related mortality was higher in group B (8.3% vs. = 0%, p < .001). Type IA endoleak was high in both groups at completion angiography (11.3% in Group A vs. 12.5% in Group B) and at follow-up (10.4% in Group A vs. 4.5% in Group B) without significant difference between the groups. Conclusions: Our data did not show a benefit of the primary use of the chimney technique in patients with a hyperangulated and short neck, although more studies are required to support this conclusion. Other strategies or new technologies are required for improving EVAR results in aneurysm patients with severe angulated proximal and short neck. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 29:Number 3(2022)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 29:Number 3(2022)
- Issue Display:
- Volume 29, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 29
- Issue:
- 3
- Issue Sort Value:
- 2022-0029-0003-0000
- Page Start:
- 361
- Page End:
- 369
- Publication Date:
- 2022-06
- Subjects:
- chimney -- EVAR -- angulation -- hyperangulation -- angulated aortic neck -- aortic aneurysm -- ChEVAR
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/15266028211050315 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20570.xml