Impella 5.0 is associated with a reduction in vasoactive support and improves hemodynamics in cardiogenic shock: A single-center experience. Issue 5 (May 2022)
- Record Type:
- Journal Article
- Title:
- Impella 5.0 is associated with a reduction in vasoactive support and improves hemodynamics in cardiogenic shock: A single-center experience. Issue 5 (May 2022)
- Main Title:
- Impella 5.0 is associated with a reduction in vasoactive support and improves hemodynamics in cardiogenic shock: A single-center experience
- Authors:
- Bashline, Michael J
Rhinehart, Zachary
Kola, Olivia
Fowler, Jeffrey
Kaczorowski, David
Hickey, Gavin - Abstract:
- Background: Treatment of cardiogenic shock (CS) often requires the use of vasopressors and inotropic agents, which are associated with an increase in mortality. Data on change in vasopressor and inotrope requirements post Impella 5.0 placement is scarce. Thus, we aimed to study the ability of Impella 5.0 to reduce these requirements. Methods: Retrospective analysis of consecutive patients with CS receiving Impella 5.0 was performed. Vasopressor-Inotrope Score (VIS) and a Modified Catecholamine Equivalent score (MCES) was calculated prior to and up to 72 h post-Impella implantation. Primary outcome was change in MCES from baseline to 48-h post implantation and secondary outcomes included change in VIS, changes in MCES according to SCAI Stage and to underlying etiology, and freedom from mortality at 30-days. Results: Twenty-eight patients with median age of 61 (48, 67) years were included. Impella 5.0 was associated with significant reduction in MCES from baseline [9.7 (5.3, 17)] to 48 h [5.7 (3.8, 7.5), p = 0.001]. VIS was also significantly reduced from baseline [8.3 (3.8, 19.9)] to 48 h [5.0 (2.5, 8), p = 0.003]. MCES at 48 h was significantly reduced in patients with SCAI Stage E versus Stage C ( p = 0.026) and with acute myocardial infarction versus acute decompensated heart ( p = 0.003). Thirty-day survival was 0% in patients that had a baseline MCES ⩾ 10 without a reduction in MCES of at least 5 at 24 h. Conclusion: Impella 5.0 is associated with a significantBackground: Treatment of cardiogenic shock (CS) often requires the use of vasopressors and inotropic agents, which are associated with an increase in mortality. Data on change in vasopressor and inotrope requirements post Impella 5.0 placement is scarce. Thus, we aimed to study the ability of Impella 5.0 to reduce these requirements. Methods: Retrospective analysis of consecutive patients with CS receiving Impella 5.0 was performed. Vasopressor-Inotrope Score (VIS) and a Modified Catecholamine Equivalent score (MCES) was calculated prior to and up to 72 h post-Impella implantation. Primary outcome was change in MCES from baseline to 48-h post implantation and secondary outcomes included change in VIS, changes in MCES according to SCAI Stage and to underlying etiology, and freedom from mortality at 30-days. Results: Twenty-eight patients with median age of 61 (48, 67) years were included. Impella 5.0 was associated with significant reduction in MCES from baseline [9.7 (5.3, 17)] to 48 h [5.7 (3.8, 7.5), p = 0.001]. VIS was also significantly reduced from baseline [8.3 (3.8, 19.9)] to 48 h [5.0 (2.5, 8), p = 0.003]. MCES at 48 h was significantly reduced in patients with SCAI Stage E versus Stage C ( p = 0.026) and with acute myocardial infarction versus acute decompensated heart ( p = 0.003). Thirty-day survival was 0% in patients that had a baseline MCES ⩾ 10 without a reduction in MCES of at least 5 at 24 h. Conclusion: Impella 5.0 is associated with a significant reduction in MCES and VIS scores in patients presenting with CS with 30-day survival being dependent on MCES. … (more)
- Is Part Of:
- International journal of artificial organs. Volume 45:Issue 5(2022)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 45:Issue 5(2022)
- Issue Display:
- Volume 45, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 45
- Issue:
- 5
- Issue Sort Value:
- 2022-0045-0005-0000
- Page Start:
- 462
- Page End:
- 469
- Publication Date:
- 2022-05
- Subjects:
- Impella 5.0 -- Vasopressor Inotropic score -- Modified Catecholamine Equivalent score -- cardiogenic shock
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.1177/03913988221083993 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20574.xml