A simplified homogenization model applied to viscoelastic behavior of cortical bone at ultrasonic frequencies. (January 2022)
- Record Type:
- Journal Article
- Title:
- A simplified homogenization model applied to viscoelastic behavior of cortical bone at ultrasonic frequencies. (January 2022)
- Main Title:
- A simplified homogenization model applied to viscoelastic behavior of cortical bone at ultrasonic frequencies
- Authors:
- Aróstica, Reidmen
Aguilera, Ana
Osses, Axel
Minonzio, Jean-Gabriel - Abstract:
- Abstract: Cortical bone is a complex multiscale medium and its study is of importance for clinical fracture prevention. In particular, cortical attenuation is known to be linked with shock energy absorption and ability to resist fracture. However, the links between cortical bone absorption and its multiscale structure are still not well understood. This work is about the use of homogenized tensors in order to characterize the viscoelastic behavior of cortical bone at ultrasonic frequencies, i.e., about 0.1 to 10 MHz. Such tensors are derived from the cell problem via two-scale homogenization theory for linear elastic and Kelvin–Voigt viscoelastic descriptions. The elliptic formulations obtained from the cell problems are implemented within the range of medically-observed porosities. Microstructure is assessed considering cubic cells with cylindrical inclusion and transverse isotropic assumption. A simplified model, adding one temporal parameter τ per phase, allows a good agreement with experimental data. The corresponding attenuation is proportional to the square of the frequency, in agreement with Kramer–Kronig relations. This development is proposed in the context of robust clinical inverse problem approaches using a restricted number of parameter. Two main properties for the material filling the pores are adjusted and discussed: absorption and shear contribution. Best agreement with experimental data is observed for material inside the pores being solid and highlyAbstract: Cortical bone is a complex multiscale medium and its study is of importance for clinical fracture prevention. In particular, cortical attenuation is known to be linked with shock energy absorption and ability to resist fracture. However, the links between cortical bone absorption and its multiscale structure are still not well understood. This work is about the use of homogenized tensors in order to characterize the viscoelastic behavior of cortical bone at ultrasonic frequencies, i.e., about 0.1 to 10 MHz. Such tensors are derived from the cell problem via two-scale homogenization theory for linear elastic and Kelvin–Voigt viscoelastic descriptions. The elliptic formulations obtained from the cell problems are implemented within the range of medically-observed porosities. Microstructure is assessed considering cubic cells with cylindrical inclusion and transverse isotropic assumption. A simplified model, adding one temporal parameter τ per phase, allows a good agreement with experimental data. The corresponding attenuation is proportional to the square of the frequency, in agreement with Kramer–Kronig relations. This development is proposed in the context of robust clinical inverse problem approaches using a restricted number of parameter. Two main properties for the material filling the pores are adjusted and discussed: absorption and shear contribution. Best agreement with experimental data is observed for material inside the pores being solid and highly attenuating. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 131(2022)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 131(2022)
- Issue Display:
- Volume 131, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 131
- Issue:
- 2022
- Issue Sort Value:
- 2022-0131-2022-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-01
- Subjects:
- Cortical bone -- Homogenization theory -- Viscoelasticity -- Microstructure mechanics -- Multiscale -- Quality factor -- Attenuation -- Ultrasound
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2021.110868 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: