Gait evaluation using inertial measurement units in subjects with Parkinson's disease. (October 2018)
- Record Type:
- Journal Article
- Title:
- Gait evaluation using inertial measurement units in subjects with Parkinson's disease. (October 2018)
- Main Title:
- Gait evaluation using inertial measurement units in subjects with Parkinson's disease
- Authors:
- Zago, Matteo
Sforza, Chiarella
Pacifici, Ilaria
Cimolin, Veronica
Camerota, Filippo
Celletti, Claudia
Condoluci, Claudia
De Pandis, Maria Francesca
Galli, Manuela - Abstract:
- Abstract: We investigated whether a wearable system based on a commercial Inertial Measurement Unit (IMU) can reliably provide the main spatiotemporal gait parameters in subjects with Parkinson's disease (PD), compared to a gold-standard optoelectronic motion capture system. The gait of 22 subjects with PD (Age: 69.4 (6.1) years; UPDRS-III: 28.0 (9.2)) was recorded simultaneously with an optoelectronic system and a commercial IMU-based wearable system. Eight spatiotemporal parameters describing the step cycle (cadence, velocity, stride length, stride duration, step length, stance, swing and double support duration) were compared between the two systems. The IMU and the optical system reported comparable gait parameters, with the exception of walking velocity (optical system, 0.72 (0.27) m∙s −1 vs. IMU: 0.86 (0.26) m∙s −1, p < 0.05). Although most parameters detected by the two systems were not statistically different, some of them like stride length, double support and step duration showed notable root mean square and mean absolute errors. In conclusion, the algorithm embedded in the current release of the commercial IMU requires further improvements to be properly used with subjects with PD. Overall, the IMU system was sufficiently accurate in the assessment of fundamental gait spatiotemporal parameters. The fast and simplified data recording process allowed by wearables makes this technology appealing and represents a possible solution for the quantification of gait in theAbstract: We investigated whether a wearable system based on a commercial Inertial Measurement Unit (IMU) can reliably provide the main spatiotemporal gait parameters in subjects with Parkinson's disease (PD), compared to a gold-standard optoelectronic motion capture system. The gait of 22 subjects with PD (Age: 69.4 (6.1) years; UPDRS-III: 28.0 (9.2)) was recorded simultaneously with an optoelectronic system and a commercial IMU-based wearable system. Eight spatiotemporal parameters describing the step cycle (cadence, velocity, stride length, stride duration, step length, stance, swing and double support duration) were compared between the two systems. The IMU and the optical system reported comparable gait parameters, with the exception of walking velocity (optical system, 0.72 (0.27) m∙s −1 vs. IMU: 0.86 (0.26) m∙s −1, p < 0.05). Although most parameters detected by the two systems were not statistically different, some of them like stride length, double support and step duration showed notable root mean square and mean absolute errors. In conclusion, the algorithm embedded in the current release of the commercial IMU requires further improvements to be properly used with subjects with PD. Overall, the IMU system was sufficiently accurate in the assessment of fundamental gait spatiotemporal parameters. The fast and simplified data recording process allowed by wearables makes this technology appealing and represents a possible solution for the quantification of gait in the clinical context, especially when using a traditional 3D optoelectronic gait analysis is not possible, and when subjects are not fully cooperative. … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 42(2018)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 42(2018)
- Issue Display:
- Volume 42, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 2018
- Issue Sort Value:
- 2018-0042-2018-0000
- Page Start:
- 44
- Page End:
- 48
- Publication Date:
- 2018-10
- Subjects:
- IMU -- Wearables -- Optoelectronic motion capture -- Gait parameters -- Gait analysis
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2018.06.009 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20562.xml