Ablation using 3D maps adjusted for spatial displacement of premature ventricular complexes relative to sinus beats: Improving precision by correcting for the shift. (26th August 2019)
- Record Type:
- Journal Article
- Title:
- Ablation using 3D maps adjusted for spatial displacement of premature ventricular complexes relative to sinus beats: Improving precision by correcting for the shift. (26th August 2019)
- Main Title:
- Ablation using 3D maps adjusted for spatial displacement of premature ventricular complexes relative to sinus beats: Improving precision by correcting for the shift
- Authors:
- Steyers, Curtis M.
Sodhi, Sandeep
Faddis, Mitchell N.
Cooper, Daniel H.
Cuculich, Phillip S.
Noheria, Amit - Abstract:
- Abstract: Introduction: Point‐by‐point 3‐dimensional (3D) electroanatomic mapping (EAM) is used to guide catheter ablation of premature ventricular complexes (PVCs). Due to the differences in the spatial excursion of the cardiac chambers during cardiac cycles in PVCs vs sinus rhythm, the 3D location registration during PVCs is shifted relative to sinus rhythm. In this study, we describe our strategy to adjust for this displacement in real‐time during PVC mapping. Methods and Results: We report 21 patients who underwent catheter ablation of 23 unique PVCs using Carto 3. After mapping the earliest site for each PVC, we reregistered its 3D location to a sinus rhythm beat in real‐time, and used this to guide ablation lesion delivery. The PVC earliest location was spatially displaced from the successful ablation lesion in sinus rhythm by average 6.7 (range 3.3–13.0) mm. Offline, we subsequently analyzed 25 unique chamber maps and 606 PVC points. For each point, we reregistered the 3D location to a preceding sinus beat. The PVC points were displaced from sinus rhythm location by average 4.4 (0.3–13.7) mm. The maximally displaced point for each chamber was 7.7 (4.7–13.7) mm. The general direction of shift during PVC was leftward and inferior relative to sinus rhythm. Conclusions: During electroanatomic mapping of PVCs using the Carto 3 system, points mapped during PVCs are spatially displaced relative to their location in sinus rhythm. Electrophysiologists should recognize thisAbstract: Introduction: Point‐by‐point 3‐dimensional (3D) electroanatomic mapping (EAM) is used to guide catheter ablation of premature ventricular complexes (PVCs). Due to the differences in the spatial excursion of the cardiac chambers during cardiac cycles in PVCs vs sinus rhythm, the 3D location registration during PVCs is shifted relative to sinus rhythm. In this study, we describe our strategy to adjust for this displacement in real‐time during PVC mapping. Methods and Results: We report 21 patients who underwent catheter ablation of 23 unique PVCs using Carto 3. After mapping the earliest site for each PVC, we reregistered its 3D location to a sinus rhythm beat in real‐time, and used this to guide ablation lesion delivery. The PVC earliest location was spatially displaced from the successful ablation lesion in sinus rhythm by average 6.7 (range 3.3–13.0) mm. Offline, we subsequently analyzed 25 unique chamber maps and 606 PVC points. For each point, we reregistered the 3D location to a preceding sinus beat. The PVC points were displaced from sinus rhythm location by average 4.4 (0.3–13.7) mm. The maximally displaced point for each chamber was 7.7 (4.7–13.7) mm. The general direction of shift during PVC was leftward and inferior relative to sinus rhythm. Conclusions: During electroanatomic mapping of PVCs using the Carto 3 system, points mapped during PVCs are spatially displaced relative to their location in sinus rhythm. Electrophysiologists should recognize this phenomenon and account for the shift to guide accurate delivery of ablation lesions. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 11(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 11(2019)
- Issue Display:
- Volume 30, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2019-0030-0011-0000
- Page Start:
- 2319
- Page End:
- 2325
- Publication Date:
- 2019-08-26
- Subjects:
- catheter ablation -- electroanatomic mapping -- premature ventricular complexes
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14120 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20556.xml