Economic impact of contact force sensing in catheter ablation for atrial fibrillation. (3rd October 2019)
- Record Type:
- Journal Article
- Title:
- Economic impact of contact force sensing in catheter ablation for atrial fibrillation. (3rd October 2019)
- Main Title:
- Economic impact of contact force sensing in catheter ablation for atrial fibrillation
- Authors:
- Mansour, Moussa
Reddy, Vivek Y.
Karst, Edward
Heist, Edwin Kevin
Packer, Douglas L.
Dalal, Nirav
Agarwal, Rahul
Calkins, Hugh
Ruskin, Jeremy N.
Mahapatra, Srijoy - Abstract:
- Abstract: Aims: The TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) clinical trial compared clinical outcomes using a contact force (CF) sensing ablation catheter (TactiCath) with a catheter that lacked CF measurement. This analysis links recorded events in the TOCCASTAR study and a large claims database, IBM MarketScan®, to determine the economic impact of using CF sensing during atrial fibrillation (AF) ablation. Methods and Results: Clinical events including repeat ablation, use of antiarrhythmic drugs, hospitalization, perforation, pericarditis, pneumothorax, pulmonary edema, pulmonary vein stenosis, tamponade, and vascular access complications were adjudicated in the year after ablation. CF was characterized as optimal if greater than or equal to 90% lesion was performed with greater than or equal to 10 g of CF. A probabilistic 1:1 linkage was created for subjects in MarketScan® with the same events in the year after ablation, and the cost was evaluated over 10 000 iterations. Of the 279 subjects in TOCCASTAR, 145 were ablated using CF (57% with optimal CF), and 134 were ablated without CF. In the MarketScan® cohort, 9811 subjects who underwent AF ablation were used to determine events and costs. For subjects ablated with optimal CF, total cost was $19 271 ± 3705 in the year after ablation. For ablation lacking CF measurement, cost was $22 673 ± 3079 (difference of $3402, P < .001). In 73% of simulations, optimal CF was associatedAbstract: Aims: The TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) clinical trial compared clinical outcomes using a contact force (CF) sensing ablation catheter (TactiCath) with a catheter that lacked CF measurement. This analysis links recorded events in the TOCCASTAR study and a large claims database, IBM MarketScan®, to determine the economic impact of using CF sensing during atrial fibrillation (AF) ablation. Methods and Results: Clinical events including repeat ablation, use of antiarrhythmic drugs, hospitalization, perforation, pericarditis, pneumothorax, pulmonary edema, pulmonary vein stenosis, tamponade, and vascular access complications were adjudicated in the year after ablation. CF was characterized as optimal if greater than or equal to 90% lesion was performed with greater than or equal to 10 g of CF. A probabilistic 1:1 linkage was created for subjects in MarketScan® with the same events in the year after ablation, and the cost was evaluated over 10 000 iterations. Of the 279 subjects in TOCCASTAR, 145 were ablated using CF (57% with optimal CF), and 134 were ablated without CF. In the MarketScan® cohort, 9811 subjects who underwent AF ablation were used to determine events and costs. For subjects ablated with optimal CF, total cost was $19 271 ± 3705 in the year after ablation. For ablation lacking CF measurement, cost was $22 673 ± 3079 (difference of $3402, P < .001). In 73% of simulations, optimal CF was associated with lower cost in the year after ablation. Conclusion: Compared to ablation without CF, there was a decrease in healthcare cost of $3402 per subject in the first year after the procedure when optimal CF was used. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 11(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 11(2019)
- Issue Display:
- Volume 30, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2019-0030-0011-0000
- Page Start:
- 2302
- Page End:
- 2309
- Publication Date:
- 2019-10-03
- Subjects:
- atrial fibrillation -- contact force -- economics -- MarketScan® -- radiofrequency ablation -- TOCCASTAR
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14189 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20556.xml