Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter. (2nd September 2019)
- Record Type:
- Journal Article
- Title:
- Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter. (2nd September 2019)
- Main Title:
- Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter
- Authors:
- Berte, Benjamin
Hilfiker, Gabi
Russi, Ian
Moccetti, Federico
Cuculi, Florim
Toggweiler, Stefan
Ruschitzka, Frank
Kobza, Richard - Abstract:
- Abstract: Introduction: The CLOSE protocol combines ablation index (AI) and ≤6 mm interlesion distance using standard power settings for the treatment of atrial fibrillation (AF). The purpose was to compare the safety and efficacy of a conventional CLOSE and a higher power shorter duration (HPSD)‐CLOSE pulmonary vein isolation (PVI) strategy. Methods and Results: All consecutive patients referred for PVI were included after informed consent was obtained from them. Group 1 was treated with a standard CLOSE protocol and group 2 with a HPSD‐CLOSE protocol (45 W anterior and 35 W posterior). Procedural parameters and 6‐month follow‐up were analyzed. In total, 174 patients (group 1: n = 94 [paroxysmal: n = 74]; group 2: n = 80 [paroxysmal: n = 65], similar baseline characteristics) were included. PVI was reached in all, but procedure duration (82 ± 18 minutes vs 100 ± 22 minutes; P < .0001) and radiofrequency (RF) time (23 ± 5 minutes vs 36 ± 11 minutes; P < .0001) was shorter in group 2. First pass isolation was similar in groups 2 and 1 (left veins: 94% vs 90%; P = .42 and right veins: 83% vs 84%; P = .79, respectively). Six‐month off‐ antiarrhythmic drugs freedom of AF/AT was similar in groups 2 and 1 (82% [paroxysmal: 86%] vs 83% [paroxysmal: 88%]; P = .93, respectively). Major complications were similar (group 2: 1% vs group 1: 3%; P = .39). Conclusion: A higher‐power short duration approach can shorten a CLOSE procedure and reduce ablation time without having aAbstract: Introduction: The CLOSE protocol combines ablation index (AI) and ≤6 mm interlesion distance using standard power settings for the treatment of atrial fibrillation (AF). The purpose was to compare the safety and efficacy of a conventional CLOSE and a higher power shorter duration (HPSD)‐CLOSE pulmonary vein isolation (PVI) strategy. Methods and Results: All consecutive patients referred for PVI were included after informed consent was obtained from them. Group 1 was treated with a standard CLOSE protocol and group 2 with a HPSD‐CLOSE protocol (45 W anterior and 35 W posterior). Procedural parameters and 6‐month follow‐up were analyzed. In total, 174 patients (group 1: n = 94 [paroxysmal: n = 74]; group 2: n = 80 [paroxysmal: n = 65], similar baseline characteristics) were included. PVI was reached in all, but procedure duration (82 ± 18 minutes vs 100 ± 22 minutes; P < .0001) and radiofrequency (RF) time (23 ± 5 minutes vs 36 ± 11 minutes; P < .0001) was shorter in group 2. First pass isolation was similar in groups 2 and 1 (left veins: 94% vs 90%; P = .42 and right veins: 83% vs 84%; P = .79, respectively). Six‐month off‐ antiarrhythmic drugs freedom of AF/AT was similar in groups 2 and 1 (82% [paroxysmal: 86%] vs 83% [paroxysmal: 88%]; P = .93, respectively). Major complications were similar (group 2: 1% vs group 1: 3%; P = .39). Conclusion: A higher‐power short duration approach can shorten a CLOSE procedure and reduce ablation time without having a negative impact on safety or efficiency. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 11(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 11(2019)
- Issue Display:
- Volume 30, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2019-0030-0011-0000
- Page Start:
- 2199
- Page End:
- 2204
- Publication Date:
- 2019-09-02
- Subjects:
- ablation -- atrial fibrillation -- CLOSE protocol -- efficiency -- high power short duration
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14122 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20556.xml