System performance evaluation of the cobas t 711 and cobas t 511 coagulation analyzers in routine laboratory settings. Issue 7 (October 2020)
- Record Type:
- Journal Article
- Title:
- System performance evaluation of the cobas t 711 and cobas t 511 coagulation analyzers in routine laboratory settings. Issue 7 (October 2020)
- Main Title:
- System performance evaluation of the cobas t 711 and cobas t 511 coagulation analyzers in routine laboratory settings
- Authors:
- Kitchen, Steve
de Maat, Moniek
Nagler, Michael
Jones, Robert
Lowe, Anna
Burden, John
Groneberg, Kai
Rozsnyai, Gergely - Abstract:
- Abstract : N/A: Utility of coagulation analyzers in real-world settings depends on characteristics that are often not studied comprehensively. This study aimed to investigate the analytical performance, system functionality, practicability, consistency and throughput of two new automated coagulation analyzers in routine laboratory practice. Real-world settings were simulated in three major European hemostasis laboratories and multiple assays were performed in anonymized plasma samples in parallel with routine clinical practice on the cobas t 711 (high-throughput) and cobas t 511 (mid-throughput) analyzers using activated partial thromboplastin time (aPTT), aPTT Lupus, aPTT Screen, Antithrombin (AT), D-Dimer, Fibrinogen, Prothrombin Time (PT)-derived Fibrinogen, PT Owren, PT Rec (recombinant human thromboplastin reagent) and Thrombin Time assays. Precision was tested in a 21-day experiment and accuracy was compared with reference methods of the same laboratory. A number of experiments simulated challenging real-life situations. Pearson's correlation coefficient was more than 0.98 in all assays. Across assays, coefficients of variation ranged from 0.0 to 1.5% for intermediate precision; 0.2 to 3.0% for repeatability and 0.4 to 3.7% for total precision. Good between-run comparability was seen when testing samples under random conditions. Calculated maximum throughput was 197 and 387–402 tests/h for the cobas t 511 and 711 analyzers, respectively. Practicability met or exceededAbstract : N/A: Utility of coagulation analyzers in real-world settings depends on characteristics that are often not studied comprehensively. This study aimed to investigate the analytical performance, system functionality, practicability, consistency and throughput of two new automated coagulation analyzers in routine laboratory practice. Real-world settings were simulated in three major European hemostasis laboratories and multiple assays were performed in anonymized plasma samples in parallel with routine clinical practice on the cobas t 711 (high-throughput) and cobas t 511 (mid-throughput) analyzers using activated partial thromboplastin time (aPTT), aPTT Lupus, aPTT Screen, Antithrombin (AT), D-Dimer, Fibrinogen, Prothrombin Time (PT)-derived Fibrinogen, PT Owren, PT Rec (recombinant human thromboplastin reagent) and Thrombin Time assays. Precision was tested in a 21-day experiment and accuracy was compared with reference methods of the same laboratory. A number of experiments simulated challenging real-life situations. Pearson's correlation coefficient was more than 0.98 in all assays. Across assays, coefficients of variation ranged from 0.0 to 1.5% for intermediate precision; 0.2 to 3.0% for repeatability and 0.4 to 3.7% for total precision. Good between-run comparability was seen when testing samples under random conditions. Calculated maximum throughput was 197 and 387–402 tests/h for the cobas t 511 and 711 analyzers, respectively. Practicability met or exceeded user expectations in 98% of cases. In a simulated real-life setting of three major laboratories, the new cobas t 511 and cobas t 711 coagulation analyzers demonstrated a good functionality, practicability and performance and the throughput was high. Abstract : Supplemental Digital Content is available in the text … (more)
- Is Part Of:
- Blood coagulation and fibrinolysis. Volume 31:Issue 7(2020)
- Journal:
- Blood coagulation and fibrinolysis
- Issue:
- Volume 31:Issue 7(2020)
- Issue Display:
- Volume 31, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 7
- Issue Sort Value:
- 2020-0031-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- activated partial thromboplastin time -- blood coagulation test -- D-Dimer -- fibrinogen -- thrombin time
Blood -- Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
Blood Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
612.115 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001721-000000000-00000 ↗
http://www.bloodcoagulation.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBC.0000000000000947 ↗
- Languages:
- English
- ISSNs:
- 0957-5235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2112.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 20522.xml