Global sensitivity analysis of skeletal muscle dMRI metrics: Effects of microstructural and pulse parameters. Issue 4 (15th October 2019)
- Record Type:
- Journal Article
- Title:
- Global sensitivity analysis of skeletal muscle dMRI metrics: Effects of microstructural and pulse parameters. Issue 4 (15th October 2019)
- Main Title:
- Global sensitivity analysis of skeletal muscle dMRI metrics: Effects of microstructural and pulse parameters
- Authors:
- Naughton, Noel M.
Georgiadis, John G. - Abstract:
- Abstract : Purpose: Estimating microstructural parameters of skeletal muscle from diffusion MRI (dMRI) signal requires understanding the relative importance of both microstructural and dMRI sequence parameters on the signal. This study seeks to determine the sensitivity of dMRI signal to variations in microstructural and dMRI sequence parameters, as well as assess the effect of noise on sensitivity. Methods: Using a cylindrical myocyte model of skeletal muscle, numerical solutions of the Bloch‐Torrey equation were used to calculate global sensitivity indices of dMRI metrics (FA, RD, MD, λ 1, λ 2, λ 3 ) for wide ranges of microstructural and dMRI sequence parameters. The microstructural parameters were: myocyte diameter, volume fraction, membrane permeability, intra‐ and extracellular diffusion coefficients, and intra‐ and extracellular T 2 times. Two separate pulse sequences were examined, a PGSE and a generalized diffusion‐weighted sequence that accommodates a larger range of diffusion times. The effect of noise and signal averaging on the sensitivity of the dMRI metrics was examined by adding synthetic noise to the simulated signal. Results: Among the examined parameters, the intracellular diffusion coefficient has the strongest effect, and myocyte diameter is more influential than permeability for FA and RD. The sensitivity indices do not vary significantly between the two pulse sequences. Also, noise strongly affects the sensitivity of the dMRI signal to microstructuralAbstract : Purpose: Estimating microstructural parameters of skeletal muscle from diffusion MRI (dMRI) signal requires understanding the relative importance of both microstructural and dMRI sequence parameters on the signal. This study seeks to determine the sensitivity of dMRI signal to variations in microstructural and dMRI sequence parameters, as well as assess the effect of noise on sensitivity. Methods: Using a cylindrical myocyte model of skeletal muscle, numerical solutions of the Bloch‐Torrey equation were used to calculate global sensitivity indices of dMRI metrics (FA, RD, MD, λ 1, λ 2, λ 3 ) for wide ranges of microstructural and dMRI sequence parameters. The microstructural parameters were: myocyte diameter, volume fraction, membrane permeability, intra‐ and extracellular diffusion coefficients, and intra‐ and extracellular T 2 times. Two separate pulse sequences were examined, a PGSE and a generalized diffusion‐weighted sequence that accommodates a larger range of diffusion times. The effect of noise and signal averaging on the sensitivity of the dMRI metrics was examined by adding synthetic noise to the simulated signal. Results: Among the examined parameters, the intracellular diffusion coefficient has the strongest effect, and myocyte diameter is more influential than permeability for FA and RD. The sensitivity indices do not vary significantly between the two pulse sequences. Also, noise strongly affects the sensitivity of the dMRI signal to microstructural variations. Conclusions: With the identification of key microstructural features that affect dMRI measurements, the reported sensitivity results can help interpret dMRI measurements of skeletal muscle in terms of the underlying microstructure and further develop parsimonious dMRI models of skeletal muscle. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 4(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 4(2020)
- Issue Display:
- Volume 83, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 4
- Issue Sort Value:
- 2020-0083-0004-0000
- Page Start:
- 1458
- Page End:
- 1470
- Publication Date:
- 2019-10-15
- Subjects:
- Bloch‐Torrey equation -- diffusion MRI -- lattice Boltzmann method -- sensitivity analysis -- skeletal muscle
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28014 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20470.xml