Insights into tissue microstructure using a double diffusion encoding sequence on a clinical scanner: Validation and application to experimental tumor models. Issue 4 (8th October 2019)
- Record Type:
- Journal Article
- Title:
- Insights into tissue microstructure using a double diffusion encoding sequence on a clinical scanner: Validation and application to experimental tumor models. Issue 4 (8th October 2019)
- Main Title:
- Insights into tissue microstructure using a double diffusion encoding sequence on a clinical scanner: Validation and application to experimental tumor models
- Authors:
- Duchêne, Gaëtan
Abarca‐Quinones, Jorge
Leclercq, Isabelle
Duprez, Thierry
Peeters, Frank - Abstract:
- Abstract : Purpose: To present a double diffusion encoding MRI sequence on a clinical scanner to analyze micro‐structure and micro‐vasculature of tumors. Methods: The sequence was tested on phantoms, asparaguses, and 2 tumors allografts in a rodent. Results were analyzed using an adapted VERDICT model to estimate microstructural parameters. The technical feasibility of the sequence on a 3T clinical system was assessed on a water phantom. The accuracy of cell size estimation was assessed on asparaguses by comparison with light microscopy. Cell size estimations were also validated when limiting relative angles of diffusion encodings to 0 and 180°. Sensitivities to restricted diffusion and incoherent flow from the vasculature were investigated in experimental tumor models. Values of microstructural parameters in viable and decaying tumor tissue were compared with those obtained from histological analysis. Results: Measurements on the water phantom revealed no significant sequence artifacts and accurate apparent diffusion coefficient values within a 4% relative error. In asparaguses, quartiles and medians of pore size distributions typically deviated less than 6% from light microscopy regardless of whether the full or reduced set of relative angles was used. Signal analyses in tumors showed mixed effects of both blood flow and diffusion restriction. Microstructural parameter estimations in tumors were consistent with histology and allowed clear and histology‐proven distinctionsAbstract : Purpose: To present a double diffusion encoding MRI sequence on a clinical scanner to analyze micro‐structure and micro‐vasculature of tumors. Methods: The sequence was tested on phantoms, asparaguses, and 2 tumors allografts in a rodent. Results were analyzed using an adapted VERDICT model to estimate microstructural parameters. The technical feasibility of the sequence on a 3T clinical system was assessed on a water phantom. The accuracy of cell size estimation was assessed on asparaguses by comparison with light microscopy. Cell size estimations were also validated when limiting relative angles of diffusion encodings to 0 and 180°. Sensitivities to restricted diffusion and incoherent flow from the vasculature were investigated in experimental tumor models. Values of microstructural parameters in viable and decaying tumor tissue were compared with those obtained from histological analysis. Results: Measurements on the water phantom revealed no significant sequence artifacts and accurate apparent diffusion coefficient values within a 4% relative error. In asparaguses, quartiles and medians of pore size distributions typically deviated less than 6% from light microscopy regardless of whether the full or reduced set of relative angles was used. Signal analyses in tumors showed mixed effects of both blood flow and diffusion restriction. Microstructural parameter estimations in tumors were consistent with histology and allowed clear and histology‐proven distinctions between decaying and viable tumor tissue. Conclusions: Double diffusion encoding with clinical gradients and scan times allows characterization of restricted diffusion and micro‐circulation flow in tumors. Our estimated microstructural parameters are promising for further investigations in assessing microstructural evolutions in tumors. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 4(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 4(2020)
- Issue Display:
- Volume 83, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 4
- Issue Sort Value:
- 2020-0083-0004-0000
- Page Start:
- 1263
- Page End:
- 1276
- Publication Date:
- 2019-10-08
- Subjects:
- diffusion MRI -- double diffusion encoding -- microstructure -- PGSE -- tumors -- validation
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28012 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20470.xml