Design of a shim coil array matched to the human brain anatomy. Issue 4 (30th September 2019)
- Record Type:
- Journal Article
- Title:
- Design of a shim coil array matched to the human brain anatomy. Issue 4 (30th September 2019)
- Main Title:
- Design of a shim coil array matched to the human brain anatomy
- Authors:
- Jia, Feng
Elshatlawy, Hatem
Aghaeifar, Ali
Chu, Ying‐Hua
Hsu, Yi‐Cheng
Littin, Sebastian
Kroboth, Stefan
Yu, Huijun
Amrein, Philipp
Gao, Xiang
Yang, Wenchao
LeVan, Pierre
Scheffler, Klaus
Zaitsev, Maxim - Abstract:
- Abstract : Purpose: The purpose of this study is to introduce a novel design method of a shim coil array specifically optimized for whole brain shimming and to compare the performance of the resulting coils to conventional spherical harmonic shimming. Methods: The proposed design approach is based on the stream function method and singular value decomposition. Eighty‐four field maps from 12 volunteers measured in seven different head positions were used during the design process. The cross validation technique was applied to find an optimal number of coil elements in the array. Additional 42 field maps from 6 further volunteers were used for an independent validation. A bootstrapping technique was used to estimate the required population size to achieve a stable coil design. Results: Shimming using 12 and 24 coil elements outperforms fourth‐ and fifth‐order spherical harmonic shimming for all measured field maps, respectively. Coil elements show novel coil layouts compared to the conventional spherical harmonic coils and existing multi‐coils. Both leave‐one‐out and independent validation demonstrate the generalization ability of the designed arrays. The bootstrapping analysis predicts that field maps from approximately 140 subjects need to be acquired to arrive at a stable design. Conclusions: The results demonstrate the validity of the proposed method to design a shim coil array matched to the human brain anatomy, which naturally satisfies the laws of electrodynamics. TheAbstract : Purpose: The purpose of this study is to introduce a novel design method of a shim coil array specifically optimized for whole brain shimming and to compare the performance of the resulting coils to conventional spherical harmonic shimming. Methods: The proposed design approach is based on the stream function method and singular value decomposition. Eighty‐four field maps from 12 volunteers measured in seven different head positions were used during the design process. The cross validation technique was applied to find an optimal number of coil elements in the array. Additional 42 field maps from 6 further volunteers were used for an independent validation. A bootstrapping technique was used to estimate the required population size to achieve a stable coil design. Results: Shimming using 12 and 24 coil elements outperforms fourth‐ and fifth‐order spherical harmonic shimming for all measured field maps, respectively. Coil elements show novel coil layouts compared to the conventional spherical harmonic coils and existing multi‐coils. Both leave‐one‐out and independent validation demonstrate the generalization ability of the designed arrays. The bootstrapping analysis predicts that field maps from approximately 140 subjects need to be acquired to arrive at a stable design. Conclusions: The results demonstrate the validity of the proposed method to design a shim coil array matched to the human brain anatomy, which naturally satisfies the laws of electrodynamics. The design method may also be applied to develop new shim coil arrays matched to other human organs. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 4(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 4(2020)
- Issue Display:
- Volume 83, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 4
- Issue Sort Value:
- 2020-0083-0004-0000
- Page Start:
- 1442
- Page End:
- 1457
- Publication Date:
- 2019-09-30
- Subjects:
- cross validation -- magnetic resonance imaging -- multi‐coil -- shim coil array design -- stream function method
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28016 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20470.xml