Hyperpolarized 129Xe imaging of embryonic stem cell‐derived alveolar‐like macrophages in rat lungs: proof‐of‐concept study using superparamagnetic iron oxide nanoparticles. Issue 4 (25th September 2019)
- Record Type:
- Journal Article
- Title:
- Hyperpolarized 129Xe imaging of embryonic stem cell‐derived alveolar‐like macrophages in rat lungs: proof‐of‐concept study using superparamagnetic iron oxide nanoparticles. Issue 4 (25th September 2019)
- Main Title:
- Hyperpolarized 129Xe imaging of embryonic stem cell‐derived alveolar‐like macrophages in rat lungs: proof‐of‐concept study using superparamagnetic iron oxide nanoparticles
- Authors:
- Riberdy, Vlora
Litvack, Michael
Stirrat, Elaine
Couch, Marcus
Post, Martin
Santyr, Giles E. - Abstract:
- Abstract : Purpose: To measure regional changes in hyperpolarized 129 Xe MRI signal and apparent transverse relaxation ( T 2 ∗ ) because of instillation of SPION‐labeled alveolar‐like macrophages (ALMs) in the lungs of rats and compare to histology. Methods: MRI was performed in 6 healthy mechanically ventilated rats before instillation, as well as 5 min and 1 h after instillation of 4 million SPION‐labeled ALMs into either the left or right lung. T 2 ∗ maps were calculated from 2D multi‐echo data at each time point and changes in T 2 ∗ were measured and compared to control rats receiving 4 million unlabeled ALMs. Histology of the ex vivo lungs was used to compare the regional MRI findings with the locations of the SPION‐labeled ALMs. Results: Regions of signal loss were observed immediately after instillation of unlabeled and SPION‐labeled ALMs and persisted at least 1 h in the case of the SPION‐labeled ALMs. This was reflected in the measurements of T 2 ∗ . One hour after the instillation of SPION‐labeled ALMs, the T 2 ∗ decreased to 54.0 ± 7.0% of the baseline, compared to a full recovery to baseline after the instillation of unlabeled ALMs. Histology confirmed the co‐localization of SPION‐labeled ALMs with regions of signal loss and T 2 ∗ decreases for each rat. Conclusion: Hyperpolarized 129 Xe MRI can detect the presence of SPION‐labeled ALMs in the airways 1 h after instillation. This approach is promising for targeting and tracking of stem cells for the treatment ofAbstract : Purpose: To measure regional changes in hyperpolarized 129 Xe MRI signal and apparent transverse relaxation ( T 2 ∗ ) because of instillation of SPION‐labeled alveolar‐like macrophages (ALMs) in the lungs of rats and compare to histology. Methods: MRI was performed in 6 healthy mechanically ventilated rats before instillation, as well as 5 min and 1 h after instillation of 4 million SPION‐labeled ALMs into either the left or right lung. T 2 ∗ maps were calculated from 2D multi‐echo data at each time point and changes in T 2 ∗ were measured and compared to control rats receiving 4 million unlabeled ALMs. Histology of the ex vivo lungs was used to compare the regional MRI findings with the locations of the SPION‐labeled ALMs. Results: Regions of signal loss were observed immediately after instillation of unlabeled and SPION‐labeled ALMs and persisted at least 1 h in the case of the SPION‐labeled ALMs. This was reflected in the measurements of T 2 ∗ . One hour after the instillation of SPION‐labeled ALMs, the T 2 ∗ decreased to 54.0 ± 7.0% of the baseline, compared to a full recovery to baseline after the instillation of unlabeled ALMs. Histology confirmed the co‐localization of SPION‐labeled ALMs with regions of signal loss and T 2 ∗ decreases for each rat. Conclusion: Hyperpolarized 129 Xe MRI can detect the presence of SPION‐labeled ALMs in the airways 1 h after instillation. This approach is promising for targeting and tracking of stem cells for the treatment of lung disease. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 83:Issue 4(2020)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 83:Issue 4(2020)
- Issue Display:
- Volume 83, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 4
- Issue Sort Value:
- 2020-0083-0004-0000
- Page Start:
- 1356
- Page End:
- 1367
- Publication Date:
- 2019-09-25
- Subjects:
- alveolar‐like macrophages -- hyperpolarized -- lung -- SPIONs -- xenon
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27999 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20470.xml