The safety and efficacy of different methods for obtaining transbronchial lung cryobiopsy in diffuse lung diseases. (12th December 2017)
- Record Type:
- Journal Article
- Title:
- The safety and efficacy of different methods for obtaining transbronchial lung cryobiopsy in diffuse lung diseases. (12th December 2017)
- Main Title:
- The safety and efficacy of different methods for obtaining transbronchial lung cryobiopsy in diffuse lung diseases
- Authors:
- Dhooria, Sahajal
Mehta, Ravindra M.
Srinivasan, Arjun
Madan, Karan
Sehgal, Inderpaul Singh
Pattabhiraman, Vallandramam
Yadav, Pavan
Sivaramakrishnan, Mahadevan
Mohan, Anant
Bal, Amanjit
Garg, Mandeep
Agarwal, Ritesh - Abstract:
- Abstract: Introduction: Most data on transbronchial lung cryobiopsy (TBLC) are from single centers, with little evidence on the outcome of different methods for performing TBLC. Objective: To report the diagnostic yield and safety of TBLC with different procedural techniques. Materials and Methods: Retrospective multicenter study of subjects who underwent TBLC for the diagnosis of diffuse parenchymal lung diseases (DPLDs). The procedure was performed using various methods: flexible or rigid bronchoscopy, with or without the use of fluoroscopy or occlusion balloon. Results: In total, 128 subjects (59% women) with a mean age of 48.9 years were included. The overall diagnostic yield of TBLC was 78.1%, with a definite diagnosis on multidisciplinary discussion made in 57 (44.5%) subjects. On a multivariate analysis, the diagnostic yield was associated with the number of biopsies taken {ajdusted odds ratio [AOR] [95% confidence interval (CI)], 2.17 [1.29‐3.67]}. The incidence of pneumothorax was lower in subjects who underwent TBLC with fluoroscopic guidance (5.9% vs 20.9%), [AOR (95% CI), 0.26 (0.07‐0.94)]. Moderate‐to‐severe bleeding occurred less frequently when an occlusion balloon was used [1.8% vs 35.7%; AOR (95% CI), 0.02 (0.001‐0.18)], after adjusting for age, use of fluoroscopy, number of biopsies obtained and number of lobes sampled. Four deaths occurred; 2 because of acute exacerbation of idiopathic pulmonary fibrosis. Conclusions: Transbronchial lung cryobiopsy wasAbstract: Introduction: Most data on transbronchial lung cryobiopsy (TBLC) are from single centers, with little evidence on the outcome of different methods for performing TBLC. Objective: To report the diagnostic yield and safety of TBLC with different procedural techniques. Materials and Methods: Retrospective multicenter study of subjects who underwent TBLC for the diagnosis of diffuse parenchymal lung diseases (DPLDs). The procedure was performed using various methods: flexible or rigid bronchoscopy, with or without the use of fluoroscopy or occlusion balloon. Results: In total, 128 subjects (59% women) with a mean age of 48.9 years were included. The overall diagnostic yield of TBLC was 78.1%, with a definite diagnosis on multidisciplinary discussion made in 57 (44.5%) subjects. On a multivariate analysis, the diagnostic yield was associated with the number of biopsies taken {ajdusted odds ratio [AOR] [95% confidence interval (CI)], 2.17 [1.29‐3.67]}. The incidence of pneumothorax was lower in subjects who underwent TBLC with fluoroscopic guidance (5.9% vs 20.9%), [AOR (95% CI), 0.26 (0.07‐0.94)]. Moderate‐to‐severe bleeding occurred less frequently when an occlusion balloon was used [1.8% vs 35.7%; AOR (95% CI), 0.02 (0.001‐0.18)], after adjusting for age, use of fluoroscopy, number of biopsies obtained and number of lobes sampled. Four deaths occurred; 2 because of acute exacerbation of idiopathic pulmonary fibrosis. Conclusions: Transbronchial lung cryobiopsy was found to offer a reasonable yield in the diagnosis of DPLDs. The incidence of pneumothorax and moderate‐to‐severe bleeding was lower with the use of fluoroscopy and an occlusion balloon, respectively. … (more)
- Is Part Of:
- Clinical respiratory journal. Volume 12:Number 4(2018)
- Journal:
- Clinical respiratory journal
- Issue:
- Volume 12:Number 4(2018)
- Issue Display:
- Volume 12, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 12
- Issue:
- 4
- Issue Sort Value:
- 2018-0012-0004-0000
- Page Start:
- 1711
- Page End:
- 1720
- Publication Date:
- 2017-12-12
- Subjects:
- bronchoscopy -- cryoprobe -- diffuse parenchymal lung disease -- interstitial lung disease -- IPF -- lung biopsy -- sarcoidosis
Respiratory organs -- Diseases -- Periodicals
Respiratory organs -- Periodicals
616.24 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1752-699X ↗
http://www.blackwell-synergy.com/loi/CRJ ↗
http://ezproxy.aut.ac.nz/login?url=http://YU7RZ9HN8Y.search.serialssolutions.com/?V=1.0&L=YU7RZ9HN8Y&S=JCs&C=THCRJ&T=marc ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/crj.12734 ↗
- Languages:
- English
- ISSNs:
- 1752-6981
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.374350
British Library DSC - BLDSS-3PM
British Library STI - Digital store
British Library STI - ELD Digital store - Ingest File:
- 20493.xml