Is It Appropriate to Use the Nafion Membrane in Electrocatalytic N2 Reduction?. Issue 12 (25th August 2019)
- Record Type:
- Journal Article
- Title:
- Is It Appropriate to Use the Nafion Membrane in Electrocatalytic N2 Reduction?. Issue 12 (25th August 2019)
- Main Title:
- Is It Appropriate to Use the Nafion Membrane in Electrocatalytic N2 Reduction?
- Authors:
- Ren, Yongwen
Yu, Chang
Tan, Xinyi
Han, Xiaotong
Huang, Hongling
Huang, Huawei
Qiu, Jieshan - Abstract:
- Abstract: The electrocatalytic N2 reduction reaction (ENRR) to ammonia has attracted much attention due to the mild operating conditions, in which the Nafion membrane is generally adopted to separate the ammonia from the anode products. However, it has been mentioned that the Nafion membrane allows ammonia to pass through and traps the ammonia to some extent, but powerful confirmation experiments and effective solutions are still lacking. Herein, it is experimentally confirmed that the use of the Nafion membrane in the ENRR is inappropriate, based on the results that the ammonia can pass through the membrane, be adsorbed on the membrane, and interact with the membrane. This causes a measurement error and accelerates the membrane degradation process, which is unfavorable for ammonia quantification and the long‐term stability operation of the ENRR in practical application. Also, for the first time, a more accurate method to evaluate the activity of the ENRR electrocatalyst using a salt bridge to replace the Nafion membrane is presented. Abstract : Ammonia can pass through the Nafion membrane, be adsorbed on the membrane, and interact with the membrane, and then the transferred ammonia can be electrooxidized in the anode cell at a higher applied potential. Nafion membrane is needed to be replaced considering measurement error of ammonia quantification and the membrane degradation for poor stability.
- Is Part Of:
- Small methods. Volume 3:Issue 12(2019)
- Journal:
- Small methods
- Issue:
- Volume 3:Issue 12(2019)
- Issue Display:
- Volume 3, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 3
- Issue:
- 12
- Issue Sort Value:
- 2019-0003-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-08-25
- Subjects:
- ammonia quantification -- electrocatalytic N2 reduction -- long‐term stability operation -- Nafion membrane -- salt bridge
Nanotechnology -- Methodology -- Periodicals
Nanotechnology -- Periodicals
Periodicals
620.5028 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2366-9608 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/smtd.201900474 ↗
- Languages:
- English
- ISSNs:
- 2366-9608
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8310.049300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20454.xml