Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort. Issue 3 (4th July 2017)
- Record Type:
- Journal Article
- Title:
- Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort. Issue 3 (4th July 2017)
- Main Title:
- Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort
- Authors:
- Frangieh, Antonio H.
Ott, Ilka
Michel, Jonathan
Shivaraju, Anupama
Joner, Michael
Mayr, N. Patrick
Hengstenberg, Christian
Husser, Oliver
Pellegrini, Costanza
Schunkert, Heribert
Kastrati, Adnan
Kasel, Albert Markus - Abstract:
- ABSTRACT: Background: To describe our updated minimalist approach (MA) for transfemoral transcatheter aortic valve replacement (TF-TAVR) using the SAPIEN 3 device and its evolution, as well as associated safety and efficacy parameters from a large cohort of patients. Methods: A stepwise description of the MA technique for TAVR for 300 consecutive patients was detailed. Safety and efficacy parameters were assessed using the VARC-2 criteria at the in-hospital and 30-days follow-up. Results: A total of 300 consecutive patients (80 ± 7 years; median Logistic EuroSCORE of 11.4% [7.5–17.8]) between January 2014 and May 2016 were evaluated. TF-TAVR was performed under conscious sedation in 247 (82%) patients. Device success was achieved in 286 (95.6%) patients, and intended prosthesis performance in 289 (96.3%) patients. Significant paravalvular leak (PVL) graded more than mild was noted in 7 (2%) patients. No patient had severe PVL. All-cause mortality was noted in one (0.3%) patient in-hospital and in 2 (0.7%) patients at the 30-days follow-up. Major stroke occurred in 4 (1.3%) patients. 9 (3%) patients had major vascular complications at 30-days follow up. MACCE (VARC-2 criteria) were observed in 21 (7%) in-hospital and 25 (8.3%) at 30 days. A new permanent pacemaker implantation was required in 29 (10.7%) patients, and was reduced from 18% to 5.6% ( p = 0.001) in a subgroup analysis considering higher implantation position of the valve after the first year of experience.ABSTRACT: Background: To describe our updated minimalist approach (MA) for transfemoral transcatheter aortic valve replacement (TF-TAVR) using the SAPIEN 3 device and its evolution, as well as associated safety and efficacy parameters from a large cohort of patients. Methods: A stepwise description of the MA technique for TAVR for 300 consecutive patients was detailed. Safety and efficacy parameters were assessed using the VARC-2 criteria at the in-hospital and 30-days follow-up. Results: A total of 300 consecutive patients (80 ± 7 years; median Logistic EuroSCORE of 11.4% [7.5–17.8]) between January 2014 and May 2016 were evaluated. TF-TAVR was performed under conscious sedation in 247 (82%) patients. Device success was achieved in 286 (95.6%) patients, and intended prosthesis performance in 289 (96.3%) patients. Significant paravalvular leak (PVL) graded more than mild was noted in 7 (2%) patients. No patient had severe PVL. All-cause mortality was noted in one (0.3%) patient in-hospital and in 2 (0.7%) patients at the 30-days follow-up. Major stroke occurred in 4 (1.3%) patients. 9 (3%) patients had major vascular complications at 30-days follow up. MACCE (VARC-2 criteria) were observed in 21 (7%) in-hospital and 25 (8.3%) at 30 days. A new permanent pacemaker implantation was required in 29 (10.7%) patients, and was reduced from 18% to 5.6% ( p = 0.001) in a subgroup analysis considering higher implantation position of the valve after the first year of experience. Conclusion: MA of TF-TAVR, when simplified and standardized, is reproducible, safe and efficient, and should be encouraged to be accepted as the standard method of care. … (more)
- Is Part Of:
- Structural heart. Volume 1:Issue 3-4(2017)
- Journal:
- Structural heart
- Issue:
- Volume 1:Issue 3-4(2017)
- Issue Display:
- Volume 1, Issue 3-4 (2017)
- Year:
- 2017
- Volume:
- 1
- Issue:
- 3-4
- Issue Sort Value:
- 2017-0001-NaN-0000
- Page Start:
- 169
- Page End:
- 178
- Publication Date:
- 2017-07-04
- Subjects:
- Minimalistic approach -- Sapien 3 -- TAVR -- transfemoral
Heart -- Diseases -- Periodicals
Congenital heart disease -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular Diseases
Cardiovascular system -- Diseases
Congenital heart disease
Heart -- Diseases
Periodicals
616.12 - Journal URLs:
- http://www.tandfonline.com/loi/ushj20 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/24748706.2017.1358832 ↗
- Languages:
- English
- ISSNs:
- 2474-8706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 20489.xml